Action:
Replace the Motor Controller module if the pressure tube shows no sign of being
faulty. ( Display Module Phase 1)
39.
(00100111) Phase 1 to 6 - Pressure Tube Fault
The probable cause of this fault is that the pressure tube has become blocked or
kinked or has fallen off completely. Alternatively the pressure sensor may be faulty.
Primary Source:
Mechanical.
Action:
Check that the pressure tube is intact and not blocked with water or dirt and is not
kinked.
Secondary Source:
Motor Controller module.(Display Module Phase 1)
Action:
Replace the Motor Controller module.(Display Module Phase 1)
40.
(00101000) Phase 1 to 6 - Bowl Dis-engage Fault
While carrying out a Basket check, the Motor Controller module has found that the
basket is not engaged even though the pressure sensor indicates that the Tub is
empty. The Motor Controller module continues to check for 2 minutes, after which
time it displays this fault. The first two areas to check are the clutch and the
pressure tube. If these two appear correct, then the fault could be in the pressure
sensor in the Motor Controller module.
Primary Source:
Mechanical.
Action:
1)
Check that there are no clothes or other foreign objects preventing the clutch
from re-engaging. Excessive suds can stop the basket rotating.
2)
If the machine is empty of water, carry out a clutch disassembly procedure
and check the spline drive.
3)
Next check that the pressure tube has not come off and that it is not kinked.
Secondary Source:
Motor Controller module.(Display Module Phase 1)
Action:
Replace Motor Controller module.(Display Module Phase 1)
41.
(00101001) Phase 1 to 6 - Temperature Sensor Fault (Thermistor)
The temperature sensor is measuring temperatures above 110oC. The fault is
probably due to a short circuit in the sensor line. (Only in the Intuitive Washer and
the GW Models.)
Primary Source:
Thermistor (Phase 5 and 6) Motor Controller (Phase 1 to 4)
Action: Phase 1
1.
Check connections of the 12 way harness
2.
Check for moisture in the console area
3.
Replace Motor Controller.
4.
Replace Display Module, if the new display fixes the fault then refit the
original Motor Controller.
Phase 2 to 4
Change Motor Controller module.
Phase 5 and 6
Action:
1.
Check the connection from the thermistor the Motor Controller
2.
Check the resistance of the thermistor, should read 12.5k ohms at (20
degrees C) 68
°
F. Replace if faulty.