Measure / check the motor harness, connectors and motor for continuity. This can
be done by taking a resistance measurement between phases of the motor harness
at the Motor Controller module end. Nominal resistance should be approximately
12.2 ohms for Phase 2,3 & Phase 4. For Phase 5 Smart Drives the nominal
resistance should be approximately 32 ohms.
Secondary Source:
Motor Controller module (Phase 4) RPS (Phase 5).
Action:
Replace Motor Controller module (Phase 4) or Rotor Position Sensor (Phase 5).
192.
(11000000) Phase 4 to 5 - Motor PMW Reset Pin Connect Fault
The Motor Controller has sensed an open circuit between pins 30 and 31. The
motor cannot operate with this condition.
Primary Source:
Motor Controller module.
Action:
Replace Motor Controller module.
230.
(11100110) Phase 6 - EEPROM Value out of Range
Wrong version detected
Primary Fault:
Motor controller is the wrong version
Action:
Change motor controller
231.
(11100111) Phase 6 - MW GW Link Error
Component has failed on the display board.
Primary Fault:
Display Module fault
Action:
Replace Display module
232.
(11101000) Phase 6 - COMMS Timeout 5 Sec
IW only problem, either the Display or motor controller has not responded in time.
Primary Fault:
Display
Action:
Replace Display
Secondary Fault:
Motor controller
Action:
Replace Motor controller
233.
(11101001) Phase 6 - EEPROM Read Error
Problem reading the EEPROM data coming from the Motor controller
Primary Fault:
Motor controller faulty
Action:
Replace Motor controller
234.
(11101010) Phase 6 - Lid Lock Open Circuit
Check Harness to Lid Lock and connections at the motor controller and lid lock
ends.
Primary Fault:
Connector to the harness, either end could be at fault.
Action:
Replace Harness.
Secondary Source:
Lid Lock has failed to be activated.
Action:
Replace Lid Lock housing.
Tertiary Source:
Motor Controller has not responded to the Lid Lock being
activated
Action:
Check the lid has a Tang and is fitted correctly to activate the Lid
Lock, if this is all in order the motor controller must be at fault and needs to be
replaced.