517766
March 2003
- 27 -
Replace the Display Module.
Note:
If Smartdrive is running at well below its rated supply voltage and the pump
has operated for more than 4 seconds at the voltage this fault will also appear.
17 – 20. (00010xxx) Phase 1 – Display / Motor Controller out of Sequence
22 – 23. (000101xx) Phase 1 – Display / Motor Controller out of Sequence
Primary Source:
The Display Module and Motor Controller are running out of
sequence.
Action:
Turn the Smartdrive off at the wall and then back on again in 5 seconds. Restart.
If the fault persists, disable auto restart feature and retest. A new fault code will
appear, carry out actions necessary to fix this new fault.
25.
(00011001) Phase 5 IW – LCD Initialisation Error
The Intuitive Display has detected a problem with the LCD. Liquid Crystal Display
Primary Source:
IW Display Module
Action:
Replace IW Display Module
28 – 30. (000111xx) Phase 1 – Display / Motor Controller out of Sequence
Refer to fault code 17
32.
(00100000) Phase 1 – Pump Circuit Error
The Display Module has detected that the pump is on when it is off.
Primary Source:
Display Module
Action:
1.
Check for moisture in the console area.
2.
Replace the Display Module.
Содержание ecosmart GWL11
Страница 2: ...517766 March 2003 ...