517766
March 2003
- 31 -
3.
Replace the Motor Controller module.
42.
(00101010) Phase 1 – Rotor Fault
Primary Source:
The Motor Controller has had some confusing information
feedback.
Action:
Turn off Smartdrive at the wall and back on again after 5 seconds.
Restart.
43.
(00101011) Phase 1 to 6 - OOB Switch Fault
The Motor Controller module has found that the signal returning from the out of
balance switch indicates that the switch is permanently on or the harness to it is
disconnected.
Primary Source:
Mechanical.
Action:
1)
Check that the out of balance switch is free to move.
2)
Check that no harnesses are blocking switch movement.
3)
Check that the switch operates correctly when activated. Replace the switch
if suspect.
4)
If the out of balance micro switch shows signs of corrosion, replace the
switch and switch harness, and fit a condensation kit to the console area if
not incorporated in the top deck.
5)
Check the level of the machine and also the bias spring.
Secondary Source:
Wiring.
Action:
Check the harness to the switch is connected correctly. The terminals should be
connected to the normally closed position. If the harness terminals show signs of
corrosion, then fit a new harness.
Tertiary Source:
Motor Controller module.(Display Module Phase1 )
Action:
Replace Motor Controller module.(Display Module Phase 1)
44.
(00101100) Phase 2 to 6 - Water in Tub during Spin
The Motor Controller has sensed a water level in the Tub during spin. This may be
caused by a slow pump out rate due to a partial blockage in the pump hose or
pump.
Primary Source:
Pump System.
Action:
1)
Check that the drain hose is not squashed or kinked.
2)
Check the length of the drain hose and try to reduce the length if excessively
long. A 39 inch (1 metre) extension hose of the same diameter fitted to the
existing drain hose is the maximum allowable length.
3)
If the Tub is empty of water, remove the pump from the pump housing and
check that it is not blocked. Also check that the drain hose is not blocked.
4)
If the Tub contains water, then service the pump from the top of the machine
by removing the top deck and basket. Bail out the water, remove the pump
cap and hood and clear the pump of any obstruction.
5) Check that water is not siphoning back into the machine when the pump turns off
when the spin speed reaches 700 rpm
Secondary Source:
Motor Controller module.
Action:
Replace Motor Controller module.
Содержание ecosmart GWL11
Страница 2: ...517766 March 2003 ...
Страница 21: ...517766 March 2003 21 17 WIRING DIAGRAM ...