Installation Instructions
22.3.11
Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 5: Installation Instructions Seite/Page 79
Fig. 5.6.6-1: Water Flow Exhaust Water Separator
Water flow exhaust water Separator
The water flow on the exhaust/water separator unit has an
inner diameter (ID) of 30 mm. If the path from the water sepa-
rator to the raw water outlet is very short, the hose can be fur-
ther reduced to 1" (25mm) ID.
Fig. 5.6.6-2: Exhaust Water Separator
(1) Raw water outlet ø 30mm
(2) Hose connector ø 30mm
(3) Reducer 30/20mm (if required)
(4) Hose
(5) Hose connector
(6) Sea cock
(7) Hull outlet
(8) Hose Clips