General operation
Seite/Page 194 Panel Generator Control P6+ RE0703_Kunde_eng.R06.1 - Kapitel/Chapter 11: General operation
22.3.11
11.4 Installation of the remote control panel
11.4.1 Placement.
Install the remote control panel at a dry, good accessible and shady place.
Connect the remote control panel to the standard 12 core cable at the generator. (1:1)
11.4.2 Terminal connections
Standard for NC temperature switch configured i.e. in case of failure „open“.
Fig. 11.4.2-1: Terminal connections
Clamp no.
Clamp name
IN / OUT
Description
1
Vbat
IN
power 12V (or optional 24V, must be adjusted by jumper)
2
GND
IN
power supply -
3
T-Engine
IN
Error “coolant temperature”. Input for thermo-switch to GND. The input is adjustable for NC/NO
(N = no error) (must be adjusted by solder Jumper). The input loads the switch with
≥
22mA to
+12V (with 24V-operated internally generated). The occurrence of an error is delayed, for ana-
lysis and displayed, around 100ms. Omission not. The in/out status is indicated with red LED.
4
Water leak (Re-
place air filter)
IN
Error “water leak”. Input for sensor switch to GND. The input is adjustable for NC/NO (N = no
error) (must be adjusted by solder Jumper). The input loads the switch with
≥
10mA to +12V (with
24V-operated internally generated). The occurrence of an error is delayed, for analysis and dis-
played, around 100ms. Omission not. The input status is indicated with red LED.
The input can be used alternatively for the signal “Replace air filter” (must be adjusted by solder
Jumper). Then the signal does not lead to switching off and is indicated with yellow LED.
5
Oil-Press
IN
Error “oil pressure“. Input for oil pressure switches to GND. The input is adjustable for NC/NO
(N = no error) (must be adjusted by solder Jumper). The input loads the switch with
≥
22mA to
+12V (with 24V-operated internally generated). The occurrence of an error is delayed, for ana-
lysis and displayed, around 1s. Omission not. The input status is indicated with red LED.
6
DC-Control
IN / OUT
Load control display. Input for signal of the dynamo. The input is adjustable for GND = OK or
12V/24V = OK (must be adjusted by solder Jumper). The input loads the signal with 5mA at 12V
and 10mA at 24V. The input status is indicated with red and green LED.
The connection can supply an energizing current for the dynamo over a fixed resistor with 68R.
Either with the control panel switched on or with “Fuel pump” switched on (must be adjusted by
solder Jumper). This function is available only in 12V-operation.
7
AC-Control
IN
AC control display. Input for NC-open-collector-sensor-switch to GND (N = OK). The input loads
the switch with
≥
2,5mA to +12V (with 24V-operated internally generated). The input status is in-
dicated with red and green LED´s.
8
Heat
OUT
Output for pre-glow relays. The output is so long active, as the button “Heat” is pressed. The
output supplies, if active, the voltage of clamp 1. Additionally the output can be operated via the
button “start” (must be adjusted by solder Jumper). Consider (notes 1-4).
9
Fuel-Pump
OUT
Output for fuel pump relay. The output is active, if no error is present (inputs 3, 4, 5, 11 and 12,
if configured accordingly). The button “start” suppresses the error analysis and the output is then
also active in the case of error, if the button “start” is pressed. The output supplies, if active, the
voltage of clamp 1. Consider (notes 1-4).
10
Start
OUT
Output for starting relay. The output is active, as long as the button “start” is pressed. The output
supplies, if active, the voltage of clamp 1. Consider (notes 1-4).