Maintenance Instructions
Seite/Page 114 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 6: Maintenance Instructions
22.3.11
6.10 Replacement of the oil-cooled backend bearing
A bearing replacement should only be executed by a trained professional.
6.10.1 Exchange oil-cooled bearing
Warning!: Automatic start
DANGER TO LIFE! - Inappropriate handling can lead to health
damages or death.
The battery bank must always be disconnected (first negative pole, then plus
pole), to ensure that the generator can not be started by accident when ope-
rations at the generator itself or its electrical system shall be executed.
6.10.2 Demounting the bearing
Fig. 6.10.2-1: 3. Oil suction
Suction or discharging the oil
It is difficult to access the drain screw.
Therefore we recommend to withdraw the oil by suction by means of a gun/
syringe plus hose (from tool package). Let the generator warm up 3-5 minu-
tes, so the oil gets thinner.
Unscrew the ventilation screw (Tool: Allen wrench SW6)
Fig. 6.10.2-2: Oil suction (with syringe)
Inserting the hose through the ventilation screws’ tap hole.
Extract the oil.