Generator Faults
22.3.11
Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 7: Generator Faults Seite/Page 147
6.2 Refill cooling water.
Refill the cooling water as described in the chapter ’Maintenance’.
6.3 Defective impeller pump.
Replace the defective impeller as described in the chapter ’Maintenance’.
6.4 Air in the cooling system.
Ventilate the cooling system as described in the chapter ’Maintenance’.
6.5 Heat exchanger blocked.
Get the heat exchanger repaired at a Fischer Panda Servicepoint/Service Center.
6.6 Defective temperature switch, possibly loose contact/cable break.
Get the temperature switch repaired at a Fischer Panda Servicepoint/Service Center.
7.2 Oil level too low.
Refill oil as described in the chapter ’Maintenance’.
8.2 Connection assembly interrupted.
Repair the connection assembly.
9.1 Defective cable to the AC-Box.
Get the cable to the AC-Box exchanged by a Fischer Panda Servicepoint/Service Center.
Attention: Voltage up to 400V - Danger to life!
The operations are to be executed by a trained professional
only!
9.2 Defective cable AC out.
Get the cable AC out exchanged by a Fischer Panda Servicepoint/Service Center.
Attention: Voltage up to 400V - Danger to life!
The operations are to be executed by a trained professional
only!
9.3 Defective consumer load.
Exchange consumer load/do not operate anymore.
9.4 Missing residual magnetism.
Let the residual magnetism be restored.
Attention: Voltage up to 400V - Danger to life!
The operations are to be executed by a trained professional
only!
10.1 Air in the fuel system.
Ventilate the fuel system as described in the chapter ’Installation’.
10.2 Defective DC fuse fuel pump
Exchange the relevant fuses at the generators’ terminal block.
A defective fuse is not always visually detectable. Measure the fuse with a multimeter for connecting passage.
10.3 Incorrect attachment of the fuel pump.
Get the installation corrected at a Fischer Panda Servicepoint/Service Center.