General References and Regulations
22.3.11
General.R01.1 - Kapitel/Chapter 1: General References and Regulations Seite/Page 25
• Never smoke in the near of the batteries. Avoid naked flames or open fires. In the area of batte-
ries exists danger of explosions.
• Pay attention that no tools fall on the battery poles, if necessary cover them.
• During the installation don´t wear a wrist watch or arm jewels, you can create under these cir-
cumstances a battery short-circuit. Burning of the skin could be the result.
• Protect every battery contact against unintentional touch.
• For battery banks: Use only cyclical profoundly dischargeable batteries. Starter batteries are not
appropriate. Lead-gel batteries are commended. They are maintenance-free, profoundly dischar-
geable and not produce gas.
• Do not charge a frozen battery.
• Avoid a batterie short-curcuit.
• Take care of a good ventilation of the battery to drain off developing gas.
• The battery connection terminals must be checked of a tight contact at least before operating.
• The battery connection cable must be carefully mounted and checked about incorrect heating at
operation with load. The vibrating devices must be regulary checked about scour points and flaw
in the isolation.
Attention !! For battery charge generators (Fischer Panda AGT-DC)!
Check before installation if the battery bank voltage correspond with the generator output
voltage