Installation Instructions
Seite/Page 76 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 5: Installation Instructions
22.3.11
5.6.5.3 Example of the installation of the water collector off-center and possible effects:
The following pictures are primarily relevant for an installation of the generator with the water collector on sailing
yachts. A change in the mounting position caused by tilted position does not have to be reckoned concerning motor
yachts. Here it is only necessary to regard that the volume of the water collector is measured so large, that it can
take the entire amount of water flowing backand at the same time maintains the minimum distance of 600 mm.
A) Installation of the water collector 500 mm next to the generators center line:
Fig. 5.6.5.3-1: Water collector, 500 mm next to the center line
Fig. 5.6.5.3-2: Tilted position, 15 degrees
Tilted position 15 degrees
The distance is only 404 mm instead of the original 600 mm.
So this is very close to the critical point.