Installation Instructions
Seite/Page 80 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 5: Installation Instructions
22.3.11
5.6.7 Installation exhaust water separator
Fig. 5.6.7-1: Installation Exhaust Water Separator
If the exhaust water separator was sufficiently highly installed, a goose neck is no longer necessary. The exhaust/
water separator fulfils the same function. If the "Super silent" exhaust system were installed correctly, the generator
will not disturb your boat neighbour. The exhaust noise should be nearly inaudible. The best result is reached, if the
hose line, which derive the cooling water, is relocate on a short way "falling" directly to the outlet and this outlet is
under the waterline.
If the thru-hull exhaust outlet has to be mounted far from the generator, an exhaust-water separator must definitely
be installed. The raw water from the separator must then run along the shortest possible path is the thru-hull outlet.
For such long exhaust routes, the exhaust hose diameter should also be increased from NW40mm to NW50mm in
order to reduce the back-pressure. The exhaust may have a length of over 10m (32 ft.) if the exhaust hose diameter
is increased to 50mm. An additional outlet exhaust muffler close to the hull outlet will help further to reduce noise
emissions.
The generator will not disturb your boat neighbours, if the "Super silent Exhaust System has been correctly installed.
The exhaust noise should be almost inaudible.
1
5
6
2
3
4
1. Generator
2. Silencer / Water lock
3. Exhaust-Water-Separator
4. Silencer
5. Sea cock
6. Hull outlet
Содержание 6500 PMS
Страница 58: ...The Panda Generator Seite Page 58 Panda_6500_7mini_PMS_eng R01 Kapitel Chapter 4 The Panda Generator 22 3 11 ...
Страница 168: ...Seite Page 168 Panda PMS 8 000 NE 42 NE Manual R05 22 3 11 Leere Seite Intentionally blank Generator Faults ...
Страница 214: ...Seite Page 214 Panel Generator Control P6 RE0703_Kunde_eng R06 1 22 3 11 Leere Seite Intentionally blank Measurements ...