5.13.3 WATER PUMP EMERGENCY ACTIVATION
(fi g. 40)
To activate a pump that has stopped because of an electrical fault, remove the cap
A
on the control panel and,
using a screwdriver, act on the distributor button to activate the pump manually.
5.13.4 CLEANING PRE-FILTER OF THE WATER PUMP
(fi g. 41)
C
D
41
Before starting the daily work shift, you must clean the pre-fi lter of the water pump.
Remove the closing cap
C
from the pump, take out the pre-fi lter
D
and check whether it is dirty inside. To
remove it, use a jet of clean water or compressed air.
Finally, reposition it inside the fi ller neck and refi t the closing cap
C
.
CAUTION: Check that there is water inside th pump (see chapter 4.3.3 for the related procedure).