![Fiori DB 260 Скачать руководство пользователя страница 172](http://html.mh-extra.com/html/fiori/db-260/db-260_use-and-maintenance-manual_2290581172.webp)
172
id.:
“COM1 Injector drive system output short to BATT Injector1 or
Injector3 (4cyl engine)/Injector2 (3cyl engine) output short to BATT “
1397
3
“COM1 Injector drive system output short to GND Injector1 or
Injector3 (4cyl engine)/Injector2 (3cyl engine) output short to GND “
1397
4
COM1 Injector drive system output open load both Injector1 and
Injector4 (4cyl engine)/Injector2 (3cyl engine) open load
1397
5
Coolant fan low speed relay short to battery
1639
5
Coolant fan low speed relay short to GND
1639
6
Coolant fan high speed relay short to battery
1639
5
Coolant fan high speed relay short to GND
1639
6
Electric fan open load / short to GND/ short to battery
1639
2
Coolant fan low speed relay short to battery
1639
5
Coolant fan low speed relay short to GND
1639
6
Coolant fan high speed relay short to battery
1639
3
Coolant fan high speed relay short to GND
1639
4
Electric fan open load/short to GND/short to battery
1639
31
Hydraulic pressure sensor signal too high
1762
3
Hydraulic pressure sensor signal too low
1762
4
Hydraulic pressure sensor signal too high
1762
3
Hydraulic pressure sensor signal too low
1762
4
EGR (exhaust gas recirculation) lift sensor signal too high
2791
3
EGR (exhaust gas recirculation) lift sensor signal too low
2791
4
EGR feedback error
2791
2
EGR motor drive circuit invalid
2791
2
EGR battery/motor failure (for CAN)
2791
3
EGR feedback/position sensor/Dynamic range failure (for CAN)
2791
2
EGR no transmission/ not received failure (for CAN)
2791
19
EGR valve temperature failure (for CAN)
2791
2
EGR valve stick/initialization failure (for CAN)
2791
2
EGR (exhaust gas recirculation) lift sensor signal too High
2791
3
EGR (exhaust gas recirculation) lift sensor signal too low
2791
4
EGR battery/motor failure (for CAN)
2791
14
EGR no transmission/not received failure (for CAN)
2791
2
EGR valve temperature failure (for CAN)
2791
31
EGR valve stuck/initialization failure (for CAN)
2791
7
EGR Cleaning failure (valve stuck open/poppet much lower than normal)
2791
13
QR data is not written
2802
13
QR data error
2802 13
QR defi nition error (defi nition concerning QR correction is not right)
2802
13
CPU fault; watchdog IC fault
2802
14
CPU fault; main CPU fault
2802
14
Check sum error - fl ash area
2802
14
QR data is not written
2802
13
QR data error
2802 11
QR defi nition error (defi nition concerning QR correction is not right)
2802
9
CPU fault; watchdog IC fault
2802
31
CPU fault; main CPU fault
2802
12
Check sum error - fl ash area
2802
14
TSC1 Time out error
3349
9
TSC1 Rolling count test
3349
10
TSC1 Checksum test
3349
2
Battery 5V reference 1 circuit high (5V power supply for sensor)
3509
3
Battery 5V reference 1 circuit low (5V power supply for sensor)
3509
4
Battery 5V reference 1 circuit high (5V power supply for sensor)
3509
3
Battery 5V reference 1 circuit low (5V power supply for sensor)
3509
4
Battery 5V reference 2 circuit high (5V power supply for sensor)
3510
3
Battery 5V reference 2 circuit low (5V power supply for sensor)
3510
4
Содержание DB 260
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 22: ......
Страница 48: ...48 3 SAFETY PRECAUTIONS id DB 260 REV 00 01 07 2015 VEHICLE EXTERIOR ...
Страница 110: ......
Страница 166: ...166 TECHNICAL ANNEXES DB 260 REV 00 01 07 2015 id HYDRAULIC DIAGRAM ...
Страница 168: ......
Страница 174: ......
Страница 175: ...2013 04 08 00 02 0796 Catalog Section 78 PowerView Model PV101 C User s Guide Version3 2 ...
Страница 176: ......
Страница 183: ...00 02 0796 3 2013 04 08 Faceplate Features ...
Страница 221: ...00 02 0796 41 2013 04 08 NOTES ...
Страница 222: ...NOTES ...
Страница 223: ...NOTES ...
Страница 226: ...www fwmurphy com PV101 ...