4
OPERATION AND USE
id.:
DB 260 REV. 00 01/07/2015
This selector is used to control drum rotation. Turn the driving post towards the drum (secondary driving
direction) and follow the instructions below:
Clockwise drum rotation during concrete loading and mixing.
In neutral position, the set speed remains fi xed.
Anticlockwise drum rotation during concrete unloading.
Repeatedly act on the selector to increase the drum rotation speed. Act on the selector in opposite direction to
reduce the speed or until stopping the drum.
CAUTION: Because of minimal hydraulic leakage, the drum tends not to remain stationary.
Periodically check drum rotation by acting on the selector.
4.2.2.g - C - Drum rotation switch
(fi g. 6).
4.2.2.h - D - Reset button
(fi g. 6).
Note: if the FIORI BATCH CONTROLLER is installed on the machine, all functions of the litre
counter located on the electronic dashboard are not active, as the functions are displayed on the
operating panel.
4.2.1.i - E - Water pumps control switch
(fi g. 6).
Snap switch to turn on the four hazard warning lights.
4.2.1.j - F - Hazard light toggle switch
(fi g. 6).
Snap switch to turn on the rear working lights.
4.2.1.k - G - Working light switch
(fi g. 6).
Lights up in the presence of an engine fault; the red led on the monitor also lights up.
4.2.2.l - H -Engine fault indicator
(fi g. 6).
This button is used to reset the litre counter and the hours to the next service due.
This button is used to reset the litre counter simultaneously on the instrument panel and on the MIX
CONTROL keeping the two displays in phase.
(for litre counter programming see chapter 4.2.6).
CAUTION: The water pump and the litres of water pumped into the drum can also be controlled from
the rear of the vehicle by means of the MIX CONTROL (see chapter 4.2.6).
This switch controls the operation of the vehicle water pump.
Follow the instructions below:
1st click -
Pump on (warning light
S1
on)
2nd click -
Pump off (warning light
S1
off).
Содержание DB 260
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 22: ......
Страница 48: ...48 3 SAFETY PRECAUTIONS id DB 260 REV 00 01 07 2015 VEHICLE EXTERIOR ...
Страница 110: ......
Страница 166: ...166 TECHNICAL ANNEXES DB 260 REV 00 01 07 2015 id HYDRAULIC DIAGRAM ...
Страница 168: ......
Страница 174: ......
Страница 175: ...2013 04 08 00 02 0796 Catalog Section 78 PowerView Model PV101 C User s Guide Version3 2 ...
Страница 176: ......
Страница 183: ...00 02 0796 3 2013 04 08 Faceplate Features ...
Страница 221: ...00 02 0796 41 2013 04 08 NOTES ...
Страница 222: ...NOTES ...
Страница 223: ...NOTES ...
Страница 226: ...www fwmurphy com PV101 ...