5.9
MODBUS/TCP INTERFACE
www.maxcessintl.com
DSE-45
MI 2-315 1 A
Move VS Relative 0x5xxx
Move virtual sensor relative to its current position.
Command Syntax:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CMD
SPD LNK
UNIT
JOB
VS
5
X
X
X
Parameter1
Required
Signed value indicating the desired distance and direction to move
the specified virtual sensor. It is interpreted according to the UNIT
field described below.
Parameter2
1
Optional
Parameter used when LNK = 1 to move one or more virtual sensors
when the target virtual sensor moves.
Parameter3
1
Optional
Parameter used when SPD = 1 to control the shift speed. This
parameter is interpreted as specified by the UNIT field.
VS
Specifies the target virtual sensor to move. (0x0=VS1; 0xF=VS16).
JOB
Job number to apply the virtual sensor(s) relocation. A job number of 0 will apply the
move to the currently active job, but a value from 1 to 8 can be supplied to move the
virtual sensors of other jobs prior to selecting them.
UNIT
The UNIT field specifies the measurement units used to interpret the supplied virtual
sensor location in Parameter1. This setting also specified how the optional shift speed
is interpreted (mm/sec x 10 or inches/sec x1000).
00 = All parameters are interpreted using 0 to 65534 scaling. The optional
shift speed is treated as mm/sec x 10.
01 = Parameters are interpreted as mm x 10. Optional shift speed is
interpreted as mm/sec x 10.
10 = Parameters are interpreted as inches x 1000. Optional shift speed is
interpreted as inches/sec x 1000.
11 = Reserved, handled same as 00.
SPD
1
The SPD bit specifies the use of a shift speed parameter supplied in Parameter3.
1 = Use Parameter3 to specify the shift speed.
0 = Move the sensor(s) immediately to the specified location.
The shift speed in Parameter3 is interpreted according to the UNIT field.
LNK
1
The LNK bit specifies if one or more virtual sensors should be linked to the target
virtual sensor specified in the VS field. This allows multiple sensors to be moved
concurrently relative to the target sensor.
1 = Use the mask in Parameter2 to link one or more sensors.
0 = Parameter2 is not used.
continued