![Fife Maxcess DSE-45 Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/fife/maxcess-dse-45-series/maxcess-dse-45-series_user-manual_2288172013.webp)
3.1
INSTALLATION
www.maxcessintl.com
DSE-45
MI 2-315 1 A
Transport and storage
-
The sensor and/or the unit on which the sensor is mounted
must be secured against slipping during transport
-
The sensor must be stored in a cool, clean, and dry place;
see
Ambient Conditions, page 11.1
-
The sensor must not be stored in the vicinity of powerful
magnetic fields. The electronic components of the sensor
may be damaged.
Mounting
The DSE-45 Ultrasonic Sensor can be mounted to a square
bar using the optional mounting brackets, or by using the
incorporated mounting holes near the far corners of the
sensor housing. For complete details, refer to the
installation drawings and instruction sheets included with
your shipment.
WARNING
-
If a sensor is damaged, it must not be installed or placed
in operation.
-
All assembly tasks on the sensor must only be performed
when there is no electrical power in the system.
-
Assembly tasks and mechanical settings must only be
performed when the machine has been stopped and
secured from being turned on again.
Mounting location
-
Protection Class: IP65
-
Operating temperature: 5°C ... 60°C [40°F ... 140°F]
-
Relative humidity: maximum 85%
-
Operating altitude above sea level:
maximum 5000 meters [16,000 feet]
-
Protected from vibrations
-
Do not place close to strong magnetic fields;
the electronic components may be damaged.
-
Do not place close to strong electrostatic fields;
the electronic components may be damaged.
-
Do not mount in places where there is a risk of explosions.