![Fife Maxcess DSE-45 Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/fife/maxcess-dse-45-series/maxcess-dse-45-series_user-manual_2288172029.webp)
5.6
MODBUS/TCP INTERFACE
www.maxcessintl.com
DSE-45
MI 2-315 1 A
Cancel
0x1000
Cancel any pending operation. This command can also be
used to "ping" the sensor to verify its presence.
Command Syntax:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CMD
SPD LNK
UNIT
JOB
VS
1
0
0
0
Parameter1 Not used.
Parameter2 Not used.
Parameter3 Not used.
Response:
RemReqCmd
Duplicates the supplied command.
RemReqStatus
1 = Command completed.
RemReqParam1
Not used.
Select Job
0x20x0
Select a new job.
Command Syntax:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CMD
SPD LNK
UNIT
JOB
VS
2
0
X
0
Parameter1
Not used
Parameter2
Not used
Parameter3
Not used
JOB
New job number 1 through 8. The requested job number must have been previously
enabled or the command fails.
Response:
RemReqCmd
Duplicates the supplied command.
RemReqStatus
1 = Command completed.
-2 = Invalid job.
RemReqParam1
Not used.