4.2
OPERATION OVERVIEW
www.maxcessintl.com
DSE-45
MI 2-315 1 A
Digital outputs
The digital outputs are transmitted via a proprietary Fife
MAXNET Serial Protocol over Ethernet, which requires an
optional Ethernet cable connected to a network device.
For more information about the available signals;
see
DSE-45 Web Page, page 6.6.
Sensor jobs
The DSE-45 supports storage for up to eight different jobs. A
job contains the sensor operation mode (single or multiple
proportional bands), the proportional band size, and all
learned virtual sensor parameters.
The DSE-45 default has only a single job enabled and is
configured as a single proportional band.
Recalling a stored job immediately activates the position and
proportional bands for all virtual sensors.
Select job; page 8.5
In order to use more than one job, additional configured jobs
must first be enabled;
Control Options, page 8.7.