9.2
SPECIFIC PROCEDURES
www.maxcessintl.com
DSE-45
MI 2-315 1 A
Application filtering
Refer to the Application Filtering Examples on the pages
following these
The DSE-45 can be configured so that a D-MAX Operator
Interface (OI) will be denied communication with the DSE-45.
This may be desired so that unauthorized personnel do not
have access to the internal settings of the DSE-45.
For further explanation and examples of Application Filtering,
refer to:
D-MAX User Manual, Figure Sheet 1-886 or
D-MAXE User Manual, Figure Sheet 2-296
Configuring the system for application filtering
To configure the system for Application Filtering, the
Application ID number and Sub Function number must be
assigned to each DSE-45 from an operator interface that has
filtering turned off.
-
The Application ID Number (1 thru 31) represents an
application group of devices. An application can be made up
of one or more devices; it may consist of just one DSE-45.
All devices in an application group must have a common
application ID number. Each application group must have a
unique Application ID number. The application ID is used to
determine the order that the devices are displayed in the list
of devices on the "All Devices" screen of the operator
interface.
continued