9.5
SPECIFIC PROCEDURES
www.maxcessintl.com
DSE-45
MI 2-315 1 A
Configure the operator interface
The next step is to configure the Operator Interface unit(s) that
will be communicating with the configured DSE-45 sensor(s) by
performing the procedure for your chosen option.
Option 1.
To "hide" a DSE-45 sensor so that it does not show up in the
list of devices on the operator interface, perform the following
procedure.
Press longer than two seconds
1.a
or
Control Options
1.a.2
or
Application Filter
1.a.2.2
1.
From the home screen of the operator interface, press and
hold the SELECT (A) key for at least two seconds to obtain
access to the Operator Interface Local Menus, and then
press the F6 key to enter the OI Menus.
2.
In the OI Menus, select "Control Options"; press ENTER.
3.
Select "Application Filter"; press ENTER.
4.
Select "Filter Type"; press ENTER.
5.
Select "Selected Application", and then press ENTER to
store the change.
6.
Next, select "Select Application"; press ENTER.
7.
Use the arrow keys to select a number that does NOT
match the Application ID that is configured in the DSE-45
sensor(s), and then press the ENTER key to store the new
selection. (If other devices in the network are using the
same Application ID number, it may be necessary to select
a different number in the DSE-45).
8.
Press the ESC key until the home screen is reached.
9.
Repeat this procedure on other operator interface units, as
desired.