5.11
MODBUS/TCP INTERFACE
www.maxcessintl.com
DSE-45
MI 2-315 1 A
Set PB
Size
0x9xx0
Set the virtual sensor proportional band size.
Command Syntax:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CMD
SPD LNK
UNIT
JOB
VS
9
X
X
0
Parameter1
Required
Specifies the new virtual sensor proportional band size. All virtual
sensors in the selected job will use the specified size.
Parameter2
Not used
Parameter3
Not used
JOB
Job number to set proportional band. A job number of 0 will change the proportional
band size of the currently active job. A value from 1 to 8 can be supplied to change the
proportional band size of other jobs prior to selecting them.
UNIT
The UNIT field specifies the measurement units used to interpret the supplied virtual
sensor proportional band size in Parameter1.
00 = Size in Parameter1 is scaled from 0 to 65534 (complete field of view).
01 = Size in Parameter1 is interpreted as mm x 10.
10 = Size in Parameter1 is interpreted as inches x 1000.
11 = Reserved, handled same as 00.
Response:
RemReqCmd
Duplicates the supplied command.
RemReqStatus
1 = Command completed.
-2 = Invalid job.
-5 = Invalid parameter.
RemReqParam1
Not used.