4. Commissioning
4-32
Festo P.BE-SBO-Q-EN en 1602e
Signal sequence with system parameters
The signal sequence using system parameters in the
“Free run” evaluation mode could appear as follows.
Power
Trig. ignored,
wait O0=1
Immediate start of evaluation,
since trigger is still 1
Cycle duration =
Earliest start of output after
Cycle start +
Wait for next trigger
Cycle duration =
Waiting for image eval
Wait for next trigger
Fig. 1 Cycle duration
Img.1
Output valid
Img.1
Lighting
Img.2
Lighting
Outputs
write
Outputs
write
Img.2
Output valid
Permanent trigger
Img.1 Image
eval. short
Wait
Img.2
Image evaluation long
Trig. ignored,
wait
Fig. 2 Cycle duration
Trig. ignored,
wait
I0
O0
Output invalid
O2
Internal & external outputs O1, LED D, CP/I/Os, EasyIP
5
6
5
6
2
2
2
2
1
3
1
3
4
Fig. 4/9:
“Free run” evaluation mode – Signal sequence using system parameters
Settings of the system parameters:
1
Earliest start of output
after cycle start=220ms
2
Ignore trigger signal
after ready for operation=65ms
3
Start of image evaluation
after cycle start=20ms
4
Function at O2 = external lighting,
start of lighting and duration of
lighting = manual
5
Start of lighting after
trigger / cycle start = 40 ms
6
Duration of lighting = 100 ms
–
Reset outputs at outputs after “Ignore
triggering signal” = Off
–
Reset outputs at outputs during
Analysis = No
Содержание SBO***-Q Series
Страница 2: ......
Страница 19: ...System overview 1 1 Festo P BE SBO Q EN en 1602e Chapter 1 System overview...
Страница 39: ...Mounting 2 1 Festo P BE SBO Q EN en 1602e Chapter 2 Mounting...
Страница 47: ...Installation 3 1 Festo P BE SBO Q EN en 1602e Chapter 3 Installation...
Страница 62: ...3 Installation 3 16 Festo P BE SBO Q EN en 1602e...
Страница 63: ...Commissioning 4 1 Festo P BE SBO Q EN en 1602e Chapter 4 Commissioning...
Страница 162: ...4 Commissioning 4 100 Festo P BE SBO Q EN en 1602e Fig 4 34 Structure of an imported data type...
Страница 175: ...Diagnostics and error handling 5 1 Festo P BE SBO Q EN en 1602e Chapter 5 Diagnostics and error handling...
Страница 183: ...Technical appendix A 1 Festo P BE SBO Q EN en 1602e Appendix A Technical appendix...
Страница 247: ...Index B 1 Festo P BE SBO Q EN en 1602e Appendix B Index...
Страница 248: ...B Index B 2 Festo P BE SBO Q EN en 1602e Table of contents B Index B 1...