4. Commissioning
4-92
Festo P.BE-SBO-Q-EN en 1602e
4.10.12 Use of the Ethernet interface with EasyIP
The device makes the EtherNet/IP protocol available for
communication with a higher-level controller.
This allows comprehensive exchange of data and control of
the device. Data can be preprocessed in the Compact Vision
System or directly transmitted to the controller for further
processing.
Read/write processes are performed via the defined
EtherNet/IP objects, which allow access not just to I/O data
but also to system parameters.
Certain memory addresses can be both read and written to,
while others can only be read or only written to (
è
tables in
Commissioning:
1. Switch the system off in order to avoid faults or damage.
Disconnect the power supply to the Compact Vision
System and the device to be coupled.
2. Using the specified cables, connect the Compact Vision
System to the device to be connected, e.g. via an Ethernet
switch or hub.
3. Reconnect the power supply.
4. Set up a connection to the Compact Vision System using
the “CheckKon” program and set the system parameters
under “Ethernet interface”:
–
The system parameter “EtherNet/IP Server” activates
the EtherNet/IP function.
Notification of slave features using “EDS Hardware
Installation Tool (Rockwell Automation)”
When you commission a new EtherNet/IP slave for the first
time, this allows the system to be notified of its characterist
ics in advance. This has the advantage that the device is
correctly identified in a scan and does not require further
configuration.
Содержание SBO***-Q Series
Страница 2: ......
Страница 19: ...System overview 1 1 Festo P BE SBO Q EN en 1602e Chapter 1 System overview...
Страница 39: ...Mounting 2 1 Festo P BE SBO Q EN en 1602e Chapter 2 Mounting...
Страница 47: ...Installation 3 1 Festo P BE SBO Q EN en 1602e Chapter 3 Installation...
Страница 62: ...3 Installation 3 16 Festo P BE SBO Q EN en 1602e...
Страница 63: ...Commissioning 4 1 Festo P BE SBO Q EN en 1602e Chapter 4 Commissioning...
Страница 162: ...4 Commissioning 4 100 Festo P BE SBO Q EN en 1602e Fig 4 34 Structure of an imported data type...
Страница 175: ...Diagnostics and error handling 5 1 Festo P BE SBO Q EN en 1602e Chapter 5 Diagnostics and error handling...
Страница 183: ...Technical appendix A 1 Festo P BE SBO Q EN en 1602e Appendix A Technical appendix...
Страница 247: ...Index B 1 Festo P BE SBO Q EN en 1602e Appendix B Index...
Страница 248: ...B Index B 2 Festo P BE SBO Q EN en 1602e Table of contents B Index B 1...