4. Commissioning
4-88
Festo P.BE-SBO-Q-EN en 1602e
RDO – Read Data Output
RDO [name of data output]
RDO “name of data output”
Outputs the values of the respective data output.
Note
Data outputs can only be requested if they have been
created previously in CheckOpti with the corresponding
name.
If no data output has been created, an error message
appears.
Details of configuration of a data output can be found in
the CheckOpti online Help.
Values are output only if the data output name has been
entered completely and correctly.
Do
not
use any of the following characters in data out
put names:
– square brackets [ ]
– quotation marks “ ”
– umlauts
– special characters.
Use correct capitalisation in data output names.
If the data output exists and uses the Telnet XML function,
you will receive
the result in the following format:
<Camera>
<DataResult_RDO>
<Name of data output>
<float32_1>RESULT VALUE_1</float32_1>
<float32_2>RESULT VALUE_2</float32_2>
:
<string_1>RESULT VALUE_N</string_1>
:
</Name of data output>
</DataResult_RDO>
</Camera>
Содержание SBO***-Q Series
Страница 2: ......
Страница 19: ...System overview 1 1 Festo P BE SBO Q EN en 1602e Chapter 1 System overview...
Страница 39: ...Mounting 2 1 Festo P BE SBO Q EN en 1602e Chapter 2 Mounting...
Страница 47: ...Installation 3 1 Festo P BE SBO Q EN en 1602e Chapter 3 Installation...
Страница 62: ...3 Installation 3 16 Festo P BE SBO Q EN en 1602e...
Страница 63: ...Commissioning 4 1 Festo P BE SBO Q EN en 1602e Chapter 4 Commissioning...
Страница 162: ...4 Commissioning 4 100 Festo P BE SBO Q EN en 1602e Fig 4 34 Structure of an imported data type...
Страница 175: ...Diagnostics and error handling 5 1 Festo P BE SBO Q EN en 1602e Chapter 5 Diagnostics and error handling...
Страница 183: ...Technical appendix A 1 Festo P BE SBO Q EN en 1602e Appendix A Technical appendix...
Страница 247: ...Index B 1 Festo P BE SBO Q EN en 1602e Appendix B Index...
Страница 248: ...B Index B 2 Festo P BE SBO Q EN en 1602e Table of contents B Index B 1...