FED ALL
(d)
Start ECAM system
(Ref. 31-51-00, P. Block 201 )
(e)
Test FANS MONITOR MFAs
(Ref. 33-17-00, P. Block
501 ) .
FED 416-422,453-499
(2)
Test
(a)
Test operation of BULK cargo compartment isolation
valve 19HN, extraction fan 30HN, and FANS MONITOR
MFA 8HN.
1)
Initial conditions:
On COMPT TEMP panel 437VU:
-
BULK CARGO temperature selector switch 14HN
is in MAN position.
-
BULK CARGO/ISOL VALVE pushbutton switch 6HN
is released OFF.
On maintenance panel 472VU:
-
ANN LT toggle switch 2WB is in READ
position.
2)
Perform test.
(2)
FED 401-405,407-414,423-436,443,445-452
Test
NOTE :
Following tests apply for both FWD and BULK
cargo compartments.
Component FINs for FWD compartment are shown
in brackets.
(a)
Test operation of BULK (FWD) cargo compartment
isolation valve 19HN (60HN), extraction fan 30HN
(48HN), and FANS MONITOR MFA 8HN (57HN).
1)
Initial conditions:
On COMPT TEMP panel 437VU:
-
BULK CARGO (FWD CARGO) temperature selector
switch 14HN (53HN) is in MAN position.
-
BULK CARGO/ISOL VALVE (FWD CARGO/ISOL
VALVE) pushbutton switch 6HN (52HN) is
released OFF.
On maintenance panel 472VU:
-
ANN LT toggle switch 2WB is in READ
position.
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 4 of 106
JUN 01/2012