(FWD CARGO) temp selector arrow remains stationary.
switch 14HN (53HN) in MAN-HOT
position until hot trim air valve
flap position arrow on R ECAM
display - AIR COND page is between
H and C, then release selector switch.
2. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow with scale appears.
3. ON COMPT TEMP panel 437VU:
- rotate and hold BULK CARGO - hot trim air valve flap position
(FWD CARGO) temp selector arrow moves to C, then cold trim
switch 14HN (53HN) in air valve flap position arrow
MAN-COLD position. moves to open position.
- release BULK CARGO (FWD CARGO) - both trim air valve flap position
temp selector switch 14HN (53HN). arrows remain stationary.
4. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold air valve flap position
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 17 of 106
JUN 01/2012