ANN LT toggle switch 2WB is in READ
position.
2)
Perform test.
(d)
FED 423-430,443,445-450
Test operation of BULK (FWD) cargo compartment
isolation valve 19HN (60HN), hot trim air valve
20HN (61HN), cold trim air valve 81HN (69HN) and
extraction fan 30HN (48HN) when SMOKE warning is
simulated.
1)
Initial conditions:
On COMPT TEMP panel 437VU:
-
BULK CARGO (FWD CARGO) temperature selector
switch 14HN (53HN) is in MAN position.
-
BULK CARGO/ISOL VALVE (FWD CARGO/ISOL
VALVE) pushbutton switch 6HN (52HN) is
pressed in.
On maintenance panel 472VU:
-
ANN LT toggle switch 2WB is in READ
position.
On CARGO COMPT SMOKE DET panel 433VU:
-
FWD/LOOP A (21WH), FWD/LOOP B (22WH), AFT/
LOOP A 23WH, AFT/LOOP B
-
24WH, BULK/LOOP A 25WH and BULK/LOOP B 26WH
pushbutton switches are pressed in.
2)
Perform test.
FED 453-499
--------------------------------------------------------------------------------
ACTION RESULT
--------------------------------------------------------------------------------
1. On CARGO COMPT SMOKE On CARGO COMPT SMOKE
DET panel 433VU: DET panel 433VU:
- release BULK/LOOP B push- - OFF legend comes on.
button switch 26WH. On WLDP:
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 20 of 106
JUN 01/2012