- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
legend 25WH (21WH) come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- for duration of isolation valve
flap movement, BULK CARGO/ISOL
VALVE (FWD CARGO/ISOL VALVE)
pushbutton switch 6HN (52HN)
FAULT legend comes on and
then goes off.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock
(closed) position.
On L ECAM display:
SMOKE
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST