to NORM/FLT position.
11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- press BULK/LOOP B (FWD/ - OFF legend goes off.
LOOP B) pushbutton switch On WLDP:
26WH (22WH). - LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B - OFF
(FWD COMPT LOOP B - OFF)
disappears.
12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
*Before SB 31-2035
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 36 of 106
JUN 01/2012