FED 453-499
POST SB 31-2035 for A/C 453-499
1. On CARGO COMPT SMOKE On CARGO COMPT SMOKE
DET panel 433VU: DET panel 433VU:
- release BULK/LOOP B push- - OFF legend comes on.
button switch 26WH. On WLDP:
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
BULK COMPT LOOP B OFF
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate and hold BULK CARGO - trim air valve opens fully and flap
temp selector switch 14HN in position arrow remains stationary
MAN-HOT position until trim at H.
air valve flap position arrow,
on R ECAM display - AIR COND
page, is at H, then release
selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO COMPT - TEST legend off PTT pushbutton
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 102 of 106
JUN 01/2012