BULK CARGO/ISOL VALVE pushbutton switch 6HN
is pressed in.
On maintenance panel 472VU:
-
ANN LT toggle switch 2WB is in READ
position.
On CARGO COMPT SMOKE DET panel 433VU:
-
AFT/LOOP A 23WH, AFT/LOOP B 24WH, BULK/LOOP
A 25WH and BULK /LOOP B 26WH pushbutton
switches are pressed in.
2)
Perform test.
FED 431-436,451-452
(d)
Test operation of BULK (FWD) cargo compartment
isolation valve 19HN (60HN), trim air valve 20HN
(61HN) and extraction fan 30HN (48HN) when SMOKE
warning is simulated.
1)
Initial conditions:
On COMPT TEMP panel 437VU:
-
BULK CARGO (FWD CARGO) temperature selector
switch 14HN (53HN) is in MAN position.
-
BULK CARGO/ISOL VALVE (FWD CARGO/ISOL
VALVE) pushbutton switch 6HN (52HN) is
pressed in.
On maintenance panel 472VU:
-
ANN LT toggle switch 2WB is in READ
position.
2)
Perform test.
FED 401-405,407-414
(d)
Test operation of BULK (FWD) cargo compartment
isolation valve 19HN (60HN), hot trim air valve
20HN (61HN), cold trim air valve 81HN (69HN) and
extraction fan 30HN (48HN) when SMOKE warning is
simulated.
1)
Initial conditions:
On COMPT TEMP panel 437VU:
-
BULK CARGO (FWD CARGO) temperature selector
switch 14HN (53HN) is in MAN position .
-
BULK CARGO/ISOL VALVE (FWD CARGO/ISOL
VALVE) pushbutton switch 6HN (52HN) is
pressed in.
On maintenance panel 472VU:
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 19 of 106
JUN 01/2012