2)
Perform test.
FED 416-422,453-499
--------------------------------------------------------------------------------
ACTION RESULT
--------------------------------------------------------------------------------
1. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- press BULK CARGO/ISOL VALVE - OFF/R legend goes off.
pushbutton switch 6HN. - for duration of isolation valve
flap movement, ISOL VALVE push-
button switch FAULT legend
comes on and then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens,
- isolation valve color : green.
On maintenance panel 472VU:
- check that BULK/CARGO MFA does not
come on.
- rotate and hold BULK CARGO temp On R ECAM display - AIR COND page:
selector switch 14HN in MAN-HOT - trim air valve flap position arrow
position until trim air valve flap remains stationary.
position arrow, on R ECAM display -
AIR COND page, is between H and C,
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 5 of 106
JUN 01/2012