to CARGO COMPT/BULK (CARGO
COMPT/FWD/1) position.
- place CARGO COMPT/LOOP TEST
SEL toggle switch 48WH to
LOOP A position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
25WH (21WH) legend come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE
(FWD CARGO/ISOL VALVE) push-
button switch 6HN (52HN) FAULT
legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes
and color changes to amber.
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 64 of 106
JUN 01/2012