background image

 

- at location G62 open circuit          - trim air valve flap position arrow

 

breaker 37HN                            moves to C.

 

- (at location G65 open circuit

 

breaker 41HN).

 

On maintenance panel 472VU:

 

- BULK/CARGO (FWD/CARGO) MFA comes

 

on.

 

- close circuit breaker 37HN (41HN).    - BULK/CARGO (FWD/CARGO) MFA remains

 

on.

 
3. On maintenance panel 472VU:

 

- press MFA RESET pushbutton            - BULK/CARGO (FWD/CARGO) MFA goes

 

switch 20WB.                            off.

 
4. On COMPT TEMP panel 437VU:              On COMPT TEMP panel 437VU:

 

- release BULK CARGO/ISOL VALVE         - OFF/R legend comes on.

 

(FWD CARGO/ISOL VALVE) push-          - for duration of isolation valve

 

button switch 6HN (52HN).               flap movement, ISOL VALVE push-

 

button switch FAULT legend comes

 

on and then goes off.

 

On R ECAM display - AIR COND page:

 

- isolation valve closed,

 

- isolation valve color : amber.

 

On maintenance panel 472VU:

A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST

Revision 32.0

P.Blk EFFECTIVITY: FED ALL

21-64-00-05

Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 8 of 106

JUN 01/2012

Содержание A310-200 AMM

Страница 1: ...00 P Block 301 Ref 33 17 00 P Block 501 Ref 31 51 00 P Block 201 AC External Power Control Memorized Fault Annunciators ECAM Sxstem FED 401 405 407 414 423 430 443 445 POST SB 31 2059 for A C 401 405 407 414 423 430 443 445 Referenced Procedures Ref 24 41 00 P Block 301 Ref 32 00 00 P Block 501 Ref 33 17 00 P Block 501 Ref 31 51 00 P Block 201 AC External Power Control Landing Gear General Memoriz...

Страница 2: ...26 203 G28 FED 423 430 443 445 450 22VU 22VU 22VU 22VU 22VU 22VU CARGO SMOKE DET WARN CARGO SMOKE DET PWR SUPPLY AVIONICS SMOKE DET DETECTORS AVIONICS SMOKE DET DETECTORS COMPT TEMP CARGO ISOL VALVES FWD COMPT TEMP CARGO ISOL VALVES BULK 46WH 35WH 1WA 2WA 40HN 2HN 209 A25 209 A26 204 F25 204 F26 203 G27 203 G28 FED 401 405 407 414 431 436 451 452 22VU 22VU 22VU 22VU AVIONICS SMOKE DET DETECTORS AV...

Страница 3: ... H64 503 H65 503 H66 502 J64 FED 416 422 453 499 129VU 129VU 129VU 129VU 129VU 129VU LIGHTING MAINT PANEL ANN MFA LIGHTING MAINT PANEL ANN MFA LIGHTING INT LT ANN LT TEST MAN LIGHTING INT LT ANN LT TEST MAN LIGHTING INT LT ANN LT TEST MAN LIGHTING INT LT ANN LT TEST AUTO 1WB 22WB 149LP 2LP 1LP 153LP 903 S90 903 S91 902 T88 902 T89 902 T90 902 T91 FED 401 405 407 414 423 436 443 445 452 129VU 129VU...

Страница 4: ...s apply for both FWD and BULK cargo compartments Component FINs for FWD compartment are shown in brackets a Test operation of BULK FWD cargo compartment isolation valve 19HN 60HN extraction fan 30HN 48HN and FANS MONITOR MFA 8HN 57HN 1 Initial conditions On COMPT TEMP panel 437VU BULK CARGO FWD CARGO temperature selector switch 14HN 53HN is in MAN position BULK CARGO ISOL VALVE FWD CARGO ISOL VALV...

Страница 5: ...en On maintenance panel 472VU check that BULK CARGO MFA does not come on rotate and hold BULK CARGO temp On R ECAM display AIR COND page selector switch 14HN in MAN HOT trim air valve flap position arrow position until trim air valve flap remains stationary position arrow on R ECAM display AIR COND page is between H and C A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision ...

Страница 6: ...437VU release BULK CARGO ISOL VALVE OFF R legend comes on pushbutton switch 6HN for duration of isolation valve flap movement ISOL VALVE push button switch FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closed isolation valve color amber On maintenance panel 472VU check that BULK CARGO MFA does not come on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ...

Страница 7: ...BULK CARGO FWD CARGO MFA does not come on rotate and hold BULK CARGO On R ECAM display AIR COND page FWD CARGO temperature selector trim air valve flap position arrow switch 14HN 53HN in MAN HOT remains stationary position until trim air valve flap position arrow on R ECAM display AIR COND page is be tween H and C then release selector switch 2 On circuit breaker panel 125VU A310 200 AMM CARGO COM...

Страница 8: ...OMPT TEMP panel 437VU release BULK CARGO ISOL VALVE OFF R legend comes on FWD CARGO ISOL VALVE push for duration of isolation valve button switch 6HN 52HN flap movement ISOL VALVE push button switch FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closed isolation valve color amber On maintenance panel 472VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ...

Страница 9: ...n switch 4HJ is pressed in 2 Perform test ACTION RESULT 1 At rack 91VU on APU and pack temp On APU and pack temp demand demand controller 37HK controller 37HK check that electrical power is light comes on when pressed available at APU and pack temp demand controller by pressing BITE READY UNPLUG CABLE AFTER USE light make certain that BITE SWITCH is in position 1 2 On circuit breaker panel 125VU a...

Страница 10: ...re control system NOTE Position 1 Sum of outputs of pack scaling amplifiers is checked Position 2 APU speed demand signal for maximum cooling is checked Position 3 APU speed demand signal for maximum heating is checked Position 4 Bridge power supply is checked Position 5 Amplifier output is checked Position 6 Drives actuator in more heat direction Position 7 Overrides bridge output with signal to ...

Страница 11: ...is located in avionics compartment at equipment rack 91VU 1 Initial conditions On COMPT TEMP panel 437VU PACK VALVE 1 and 2 pushbutton switches 191HB and 189HB are pressed in BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN is pressed in BULK CARGO FWD CARGO temperature selector switch 14HN 53HN is in AUTO position HOT AIR SUPPLY pushbutton switch 4HJ is pressed in 2 Perform t...

Страница 12: ...ck temp demand controller at location H65 close circuit BITE READY UNPLUG CABLE AFTER breaker 5HN USE and GO indicator lights come at location H63 close circuit on breaker 43HN 5 On APU and pack temperature demand controller press NO GO indicator light NO GO integral light comes on place BITE SWITCH to positions for each position selected 1 thru 12 in sequence pausing GO indicator light must come ...

Страница 13: ...cked Position 11 Output of bridge is checked Position 12 Selector output signal is checked return BITE SWITCH to position 1 6 On circuit breaker panel 125VU On APU and pack temperature demand controller at location H65 open circuit BITE READY UNPLUG CABLE AFTER breaker 5HN USE and GO indicator lights go off at location H63 open circuit breaker 43HN 7 On BULK CARGO FWD CARGO compt temp controller d...

Страница 14: ...orm test ACTION RESULT 1 At rack 91VU on APU and pack temp On APU and pack temp demand demand controller 37HK controller 37HK check that electrical power is light comes on when pressed available at APU and pack temp demand controller by pressing BITE READY UNPLUG CABLE AFTER USE light make certain that BITE SWITCH is in position 1 2 On circuit breaker panel 125VU at location H65 open circuit break...

Страница 15: ...ws a failure in the cargo compartment temperature control system NOTE Position 1 Sum of outputs of pack scaling amplifiers is checked Position 2 APU speed demand signal for maximum cooling is checked Position 3 APU speed demand signal for maximum heating is checked Position 4 Bridge power supply is checked Position 5 Amplifier output is checked Position 6 Drives actuator in more heat direction Pos...

Страница 16: ...5VU at location H65 close circuit breaker 5HN at location H63 close circuit breaker 43HN c Test operation of cold trim air valve 81HN 69HN 1 Initial conditions ON COMPT TEMP panel 437VU BULK CARGO FWD CARGO temperature selector switch 14HN 53HN is in MAN position BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN is pressed in 2 Perform test ACTION RESULT 1 On COMPT TEMP panel 4...

Страница 17: ...ition FWD CARGO temp selector arrow moves to C then cold trim switch 14HN 53HN in air valve flap position arrow MAN COLD position moves to open position release BULK CARGO FWD CARGO both trim air valve flap position temp selector switch 14HN 53HN arrows remain stationary 4 On CARGO COOL panel 444VU On CARGO COOL panel 444VU release BULK FWD pushbutton ON legend goes off switch 80HN 78HN On L ECAM ...

Страница 18: ...20HN and extraction fan 30HN when SMOKE warning is simulated 1 Initial conditions On COMPT TEMP panel 437VU BULK CARGO temperature selector switch 14HN is in MAN position BULK CARGO ISOL VALVE pushbutton switch 6HN is pressed in On maintenance panel 472VU ANN LT toggle switch 2WB is in READ position 2 Perform test c FED 421 422 453 499 Test operation of BULK cargo compartment isolation valve 19HN ...

Страница 19: ...VALVE pushbutton switch 6HN 52HN is pressed in On maintenance panel 472VU ANN LT toggle switch 2WB is in READ position 2 Perform test FED 401 405 407 414 d Test operation of BULK FWD cargo compartment isolation valve 19HN 60HN hot trim air valve 20HN 61HN cold trim air valve 81HN 69HN and extraction fan 30HN 48HN when SMOKE warning is simulated 1 Initial conditions On COMPT TEMP panel 437VU BULK C...

Страница 20: ...in On maintenance panel 472VU ANN LT toggle switch 2WB is in READ position On CARGO COMPT SMOKE DET panel 433VU FWD LOOP A 21WH FWD LOOP B 22WH AFT LOOP A 23WH AFT LOOP B 24WH BULK LOOP A 25WH and BULK LOOP B 26WH pushbutton switches are pressed in 2 Perform test FED 453 499 ACTION RESULT 1 On CARGO COMPT SMOKE On CARGO COMPT SMOKE DET panel 433VU DET panel 433VU release BULK LOOP B push OFF legen...

Страница 21: ...on R ECAM display AIR COND page is at H then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO COMPT TEST legend off PTT pushbutton selector switch 16WA to CARGO switch 52WA comes on COMPT BULK position place CARGO COMPT LOOP TEST SEL toggle switch 48WH to LOOP A position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revisi...

Страница 22: ...isplay AIR COND page isolation valve closes and color changes to amber trim air valve flap position arrow moves to position C On L ECAM display SMOKE BULK CARGO COMPT SMOKE AGENT 1 DISCH LDG ELEVATION 10 000 FT MAX FL 100 MEA appears release PTT pushbutton switch On CARGO COMPT SMOKE DET panel 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY ...

Страница 23: ...VU reset BULK CARGO ISOL VALVE after isolation valve opens pushbutton switch 6HN ISOL VALVE pushbutton switch FAULT legend goes off On R ECAM display AIR COND page isolation valve opens and color changes to green trim air valve flap position arrow A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyri...

Страница 24: ... DET panel panel 433VU 433VU press BULK LOOP B pushbutton OFF legend goes off switch 26WH On WLDP LOOP warning light goes off On L ECAM display LOOP BULK COMPT LOOP B OFF disappears FED 453 454 456 499 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corporation Memphis TN 38...

Страница 25: ...ector switch 14HN in position arrow remains stationary MAN HOT position until trim at H air valve flap position arrow on R ECAM display AIR COND page is at H then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO COMPT TEST legend off PTT pushbutton selector switch 16WA to CARGO switch 52WA comes on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CO...

Страница 26: ...t repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE pushbutton switch 6HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber trim air valve flap position arrow moves to position C On L ECAM display A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed ...

Страница 27: ...hime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE AGENT 1 DISCH LDG ELEVATION 10 000 FT MAX FL 100 MEA disappears 5 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE after isolation valve opens A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Exp...

Страница 28: ... On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel panel 433VU 433VU press BULK LOOP B pushbutton OFF legend goes off switch 26WH On WLDP LOOP warning light goes off On L ECAM display LOOP BULK COMPT LOOP B OFF disappears FED 416 436 443 445 451 499 POST SB 31 2035 for A C 423 435 443 445 453 499 POST SB 31 2059 for A C 423 430 443 445 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUS...

Страница 29: ...on In flight compartment single chime sounds On L ECAM display LOOP BULK COMPT LOOP B OFF FWD COMPT LOOP B OFF appears 2 On COMPT TEMP panel 437VU On R ECAM display AIR COND page rotate BULK CARGO FWD CARGO hot trim air valve opens and temp selector switch 14HN remains stationary color green A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL ...

Страница 30: ...lace CARGO COMPT LOOP TEST SEL toggle switch 48WH to LOOP A position 4 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A 25WH 21WH legend come on On WLDP SMOKE warning light flashes In flight compartment A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0...

Страница 31: ...n L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT appears release PTT pushbutton switch On CARGO COMPT SMOKE DET panel 433VU BULK SMOKE FWD SMOKE red warning light and LOOP A legend go off On WLDP A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 Fe...

Страница 32: ...itch legend goes off 6HN 52HN On R ECAM display AIR COND page isolation valve opens and color changes to green hot trim air valve flap position arrow remains at position C 6 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton switch ON legend comes on 80HN 78HN On L ECAM display MEMO A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EF...

Страница 33: ...air valve flap CARGO temp selector switch position arrow remains 14HN 53HN when cold trim stationary air valve is approx half opened 8 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A legend 25WH 21WH come on On WLDP SMOKE warning light flashes A310 200 AMM CARGO COMPARTMENT TEMPERA...

Страница 34: ...ock closed position On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT appears release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch BULK SMOKE FWD SMOKE warning light and LOOP A legend go off On WLDP A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Tim...

Страница 35: ...nd goes off On R ECAM display AIR COND page isolation valve opens and color changes to green cold trim air valve flap position arrow remains at 10 o clock closed position 10 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Rev...

Страница 36: ...n CARGO COOL panel 444VU release BULK FWD pushbutton ON legend goes off switch 80HN 78HN On L ECAM display BULK CARGO COOLING ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear Before SB 31 2035 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Da...

Страница 37: ... COMPT TEMP panel 437VU On R ECAM display AIR COND page rotate BULK CARGO FWD CARGO hot trim air valve opens and temp selector switch 14HN remains stationary color green 53HN to MAN HOT position hold until hot trim air valve flap position arrow on R ECAM display AIR COND page is at least half opened A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY ...

Страница 38: ...ess and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A 25WH 21WH legend come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE push button switch 6HN 52HN FAULT legend comes on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revisio...

Страница 39: ... pushbutton switch On CARGO COMPT SMOKE DET panel 433VU BULK SMOKE FWD SMOKE red warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops On L ECAM display A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corpora...

Страница 40: ...lation valve opens and color changes to green hot trim air valve flap position arrow remains at position C 6 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton switch ON legend comes on 80HN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ...

Страница 41: ...n cold trim stationary air valve is approx half opened 8 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A legend 25WH 21WH come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO A310 200 AMM...

Страница 42: ...OKE AGENT 1 DISCH LDG ELEVATION 10 000 FT appears release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch BULK SMOKE FWD SMOKE warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx...

Страница 43: ... AIR COND page isolation valve opens and color changes to green cold trim air valve flap position arrow remains at 10 o clock closed position 10 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32...

Страница 44: ...play BULK CARGO COOLING ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear FED 423 430 443 445 PRE SB 21 2015 for A C 423 430 443 445 PRE SB 31 2023 for A C 423 430 443 445 PRE SB 31 2035 for A C 423 430 443 445 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTR...

Страница 45: ...lector switch 14HN remains stationary color green 53HN to MAN HOT position hold until hot trim air valve flap position arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0...

Страница 46: ...5WH 21WH legend come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU for duration of isolation valve flap movement BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on and then goes off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64...

Страница 47: ...U BULK CARGO FWD CARGO MFA 8HN 57HN comes on release PTT pushbutton switch On CARGO COMPT SMOKE DET panel 433VU BULK SMOKE FWD SMOKE red warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx ...

Страница 48: ...FAULT legend comes on 6HN 52HN and then goes off On R ECAM display AIR COND page isolation valve opens and color changes to green hot trim air valve flap position arrow remains at position C On maintenance panel 472VU BULK CARGO FWD CARGO MFA 8HN 57HN remains on 6 On maintenance panel 472VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 2...

Страница 49: ...37VU rotate to and hold BULK hot trim air valve flap position CARGO FWD CARGO temp arrow remains at C and cold selector switch 14HN trim air valve flap position 53HN in MAN COLD posi arrow moves to position C tion release BULK CARGO FWD cold trim air valve flap CARGO temp selector switch position arrow remains 14HN 53HN when cold trim stationary A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL A...

Страница 50: ...f isolation valve flap movement BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closes and color changes to amber cold trim air valve flap position arrow moves to 10 o clock closed position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY F...

Страница 51: ... FWD SMOKE warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE AGENT 1 DISCH A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corporation ...

Страница 52: ... position 11 On maintenance panel 472VU On maintenance panel 472VU press MFA RESET push BULK CARGO FWD CARGO MFA button switch 20WB goes off 12 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 13 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel A310 200 AMM C...

Страница 53: ...NG ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear Before SB 21 2015 Post SB 31 2023 For A C 001 009 501 501 551 551 Post SB 31 2035 For A C 001 009 501 501 551 551 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFEC...

Страница 54: ...lector switch 14HN remains stationary color green 53HN to MAN HOT position hold until hot trim air valve flap position arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0...

Страница 55: ...A 25WH 21WH legend come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU for duration of isolation valve flap movement BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN legend comes on and then goes off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00...

Страница 56: ...RGO MFA 8HN 57HN comes on release PTT pushbutton switch On CARGO COMPT SMOKE DET panel 433VU BULK SMOKE FWD SMOKE red warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 Fe...

Страница 57: ...lay AIR COND page isolation valve opens and color changes to green hot trim air valve flap position arrow remains at position C On maintenance panel 472VU BULK CARGO FWD CARGO MFA 8HN 57HN remains on 6 On maintenance panel 472VU press MFA RESET pushbutton BULK CARGO FWD CARGO MFA goes switch 20WB off and remains off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P...

Страница 58: ...ns at C and cold selector switch 14HN trim air valve flap position 53HN in MAN COLD posi arrow moves to position C tion release BULK CARGO FWD cold trim air valve flap CARGO temp selector switch position arrow remains 14HN 53HN when cold trim stationary air valve is approx half opened 9 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTR...

Страница 59: ...RGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closes and color changes to amber cold trim air valve flap position arrow moves to 10 o clock closed position On L ECAM display SMOKE A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 1...

Страница 60: ...In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT disappears 10 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE for duration of isolation valve A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 1...

Страница 61: ...intenance panel 472VU press MFA RESET push BULK CARGO FWD CARGO MFA button switch 20WB goes off 12 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 13 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONT...

Страница 62: ...NG ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear Before SB 31 2023 Before SB 31 2035 Post SB 21 2015 For A C 001 001 003 003 008 009 551 551 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED...

Страница 63: ...ationary color green 53HN to MAN HOT position hold until hot trim air valve flap position arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA comes on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT...

Страница 64: ...OKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE push button switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed ...

Страница 65: ...OKE red warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE AGENT 1 DISCH A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corporation Mem...

Страница 66: ...s at position C 6 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton switch ON legend comes on 8OHN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears On R ECAM display AIR COND page cold trim air valve flap position arrow with scale appears 7 On COMPT TEMP panel 437VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision...

Страница 67: ...DET panel 433VU press and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A legend 25WH 21WH come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page A310 200 AMM CARGO COMPAR...

Страница 68: ...O COMPT SMOKE DET panel 433VU switch BULK SMOKE FWD SMOKE warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express C...

Страница 69: ... at 10 o clock closed position 10 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 11 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU press BULK LOOP B FWD OFF legend goes off LOOP B pushbutton switch On WLDP A310 200 AMM CARGO COMPARTMENT TEMPER...

Страница 70: ...d trim air valve flap position arrow and scale disappear FED 446 450 POST SB 31 2035 for A C 446 450 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU release BULK LOOP B FWD LOOP B OFF legend comes on pushbutton switch 26WH 22WH On main instrument panels 3VU and 5VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL...

Страница 71: ...air valve flap position arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA comes on to CARGO COMPT BULK CARGO COMPT FWD 1 position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0...

Страница 72: ...ompartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber hot trim air valve flap position arrow moves to position C A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL...

Страница 73: ...ent panels 3VU and 5VU MASTER WARNING lights go off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT disappears A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corporation Memphis TN 381...

Страница 74: ...s BULK FWD pushbutton switch ON legend comes on 80HN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears On R ECAM display AIR COND page cold trim air valve flap position arrow with scale appears 7 On COMPT TEMP panel 437VU rotate and hold BULK CARGO hot trim air valve flap position FWD CARGO temp selector arrow remains at C and cold A310 200 AMM CARGO COMPARTMENT TEMPER...

Страница 75: ...52WA light 12WH 1WH and LOOP A legend 25WH 21WH come on On main instrument panels 3VU and 5VU MASTER WARNING lights flash In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJU...

Страница 76: ... BULK SMOKE FWD SMOKE warning light and LOOP A legend go off On main instrument panels 3VU and 5VU MASTER WARNING lights go off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corpora...

Страница 77: ...ion 10 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 11 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU press BULK LOOP B FWD OFF legend goes off LOOP B pushbutton switch On main instrument panels 3VU 26WH 22WH and 5VU A310 200 AMM CARGO COMPA...

Страница 78: ...ap position arrow and scale disappear FED 447 449 POST SB 31 2035 for A C 447 449 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU release BULK LOOP B FWD LOOP B OFF legend comes on pushbutton switch 26WH 22WH On main instrument panels 3VU and 5VU MASTER CAUTION lights come on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIV...

Страница 79: ...osition arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA comes on to CARGO COMPT BULK CARGO COMPT FWD 1 position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVI...

Страница 80: ...ompartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber hot trim air valve flap position arrow moves to position C A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL...

Страница 81: ...ER WARNING lights go off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT disappears 5 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express...

Страница 82: ...h ON legend comes on 80HN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears On R ECAM display AIR COND page cold trim air valve flap position arrow with scale appears 7 On COMPT TEMP panel 437VU rotate and hold BULK CARGO hot trim air valve flap position FWD CARGO temp selector arrow remains at C and cold A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TE...

Страница 83: ...52WA light 12WH 1WH and LOOP A legend 25WH 21WH come on On main instrument panels 3VU and 5VU MASTER WARNING lights flash In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJU...

Страница 84: ... FWD SMOKE warning light and LOOP A legend go off On main instrument panels 3VU and 5VU MASTER WARNING lights go off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Expr...

Страница 85: ...aintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 11 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU press BULK LOOP B FWD OFF legend goes off LOOP B pushbutton switch On main instrument panels 3VU 26WH 22WH and 5VU A310 200 AMM CARGO COMPARTMENT TEMP...

Страница 86: ...AIR COND page cold trim air valve flap position arrow and scale disappear FED 401 405 407 412 POST SB 31 2059 for A C 401 405 407 412 NOTE Setting the A C to simulated FLT CONFIG Ref 32 00 00 P Block 501 the ECAM SMOKE warning will include LAND ASAP for second priority A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Dat...

Страница 87: ...el 471VU rotate ELEC COMPT CARGO PTT pushbutton switch 52WA TEST COMPT selector switch 16WA legend comes on to CARGO COMPT BULK 1 CARGO COMPT FWD 1 position press and hold PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch 52WA after approx 2 3 second delay AFT BULK SMOKE FWD SMOKE red warning light 38WH 39WH comes on In flight compartment A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL...

Страница 88: ...es to position C On L ECAM display SMOKE AFT BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT MAX FL 100 MEA appears release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch AFT BULK SMOKE FWD SMOKE red warning light goes off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Tim...

Страница 89: ... switch FAULT VALVE pushbutton switch legend goes off 6HN 52HN On R ECAM display AIR COND page isolation valve opens and color changes to green hot trim air valve flap position arrow remains at position C 4 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton ON legend comes on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVI...

Страница 90: ...ap position position arrow moves towards position C release BULK CARGO FWD CARGO cold trim air valve flap temp selector switch 14HN position arrow remains stationary 53HN when cold trim air valve 81HN 69HN is approx half open 6 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT pushbutton after approx 2 3 second delay A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTR...

Страница 91: ...play AIR COND page isolation valve closes and color changes to amber cold trim air valve flap position arrow moves to 10 o clock closed position On L ECAM display SMOKE AFT BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12...

Страница 92: ...MEA disappears 7 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE after isolation valve opens FWD CARGO ISOL VALVE ISOL VALVE pushbutton switch FAULT pushbutton switch 6HN legend goes off 52HN On R ECAM display AIR COND page isolation valve opens and A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05...

Страница 93: ...ay AIR COND page cold trim air valve flap position arrow and scale disappear 9 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO PTT pushbutton switch 52WA TEST COMPT selector switch 16WA legend goes off to NORM FLT position FED 413 414 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 ...

Страница 94: ... R ECAM display AIR COND page is at least half opened then release selector switch 2 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO PTT pushbutton switch 52WA TEST COMPT selector switch legend comes on 16WA to CARGO COMPT BULK 1 CARGO COMPT FWD 1 position press and hold PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch 52WA after 2 3 second delay A310 200 AM...

Страница 95: ...L VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closes and color changes to amber hot trim air valve flap position arrow moves to position C On L ECAM display A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time...

Страница 96: ...e stops On L ECAM display SMOKE AFT BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT MAX FL 100 MEA disappears 3 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE for duration of isolation valve A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright...

Страница 97: ...tion C 4 On maintenance panel 472VU On maintenance panel 472VU press MFA RESET pushbutton BULK CARGO FWD CARGO MFA switch 20WB goes off 5 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton ON legend comes on switch 8OHN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revisio...

Страница 98: ... position arrow remains 14HN 53HN when cold trim stationary air valve is approx half open 7 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT pushbutton after approx 2 3 second delay switch 52WA AFT BULK SMOKE FWD SMOKE red warning light 38WH 39WH comes on In flight compartment repetitive chime sounds On WLDP SMOKE warning light flashes On COMPT TEMP panel 437VU A3...

Страница 99: ...r valve flap position arrow moves to 10 o clock closed position On L ECAM display SMOKE AFT BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT MAX FL 100 MEA appears release PTT pushbutton On CARGO COMP SMOKE DET panel 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 1...

Страница 100: ...eset BULK CARGO ISOL VALVE for duration of isolation valve FWD CARGO ISOL VALVE flap movement ISOL VALVE push pushbutton switch 6HN 52HN button switch FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve opens and color changes to green A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed D...

Страница 101: ...M display BULK CARGO COOLING ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear 11 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO PTT pushbutton switch 52WA COMPT selector switch TEST legend goes off 16WA to NORM FLT position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST ...

Страница 102: ...GO trim air valve opens fully and flap temp selector switch 14HN in position arrow remains stationary MAN HOT position until trim at H air valve flap position arrow on R ECAM display AIR COND page is at H then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO COMPT TEST legend off PTT pushbutton A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTRO...

Страница 103: ...light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE pushbutton switch 6HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber trim air valve flap position arrow moves to position C A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 6...

Страница 104: ...CAM display SMOKE BULK CARGO COMPT SMOKE AGENT 1 DISCH LDG ELEVATION 10 000 FT disappears 5 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE after isolation valve opens pushbutton switch 6HN ISOL VALVE pushbutton switch A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Cop...

Страница 105: ...WA goes off position 7 On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel panel 433VU 433VU press BULK LOOP B pushbutton OFF legend goes off switch 26WH On WLDP LOOP warning light goes off On L ECAM display LOOP BULK COMPT LOOP B OFF disappears FED 416 422 453 499 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Dat...

Страница 106: ...a On maintenance panel 472VU place ANN LT toggle switch 2WB in OFF position b On ECAM control panel release ECAM SGU 1 and 2 pushbutton switches c On COMPT TEMP panel 437VU rotate BULK CARGO FWD CARGO temperature selector switch 14HN 53HN to AUTO position d Make certain that working area is clean and clear of tools and miscellaneous items of equipment e De energize aircraft electrical network and ...