- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL - for duration of isolation valve
VALVE (FWD CARGO/ISOL flap movement, ISOL VALVE push-
VALVE) pushbutton switch button switch FAULT legend comes on
6HN (52HN). and then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- hot trim air valve flap position
arrow remains at position C.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA 8HN
(57HN) remains on.
6. On maintenance panel 472VU:
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 48 of 106
JUN 01/2012