Functional safety
FUN
C
TI
ON
AL SAFET
Y
Cabl
ing
an
d
groun
din
g
9.
Ref.1912
· 323 ·
DDS
HARDWARE
9.9 Cabling and grounding
Safety functions
The following recommendations must be taken into account when designing
the safety functions:
See ·
Drive Enable electrical protections
Try keeping power cables and signal cables apart from each other.
- KM1 contactor in case of high current:
Install an intermediate
auxiliary relay to activate the coil of the contactor for high power units
were the consumption current and peak current of the external main
contactor is significant; although the mirror contact in series with the ON
button must belong to the external main contactor, never to the
intermediate relay.
Exclusion of wiring malfunctions
The table D.4 of EN ISO 13849-2 sets out possible measures to consider to
exclude short-circuit failures between conductors.
The following measurement from the table can be applied to the cables
connected between the drive and the external safety controller but not for the
holding brake cables that go to the motor that is outside of the enclosure.
They can be excluded if the drive and the external safety controller are
within the same electrical enclosure. Provided both the conductors and
enclosure meet the appropriate requirements ·see IEC 60204-1·.
The Power Drive System, in general
The instructions regarding the cabling and grounding when installing the
system are described in chapter
in this manual.
Содержание DDS APS-24
Страница 1: ...DRIVE DDS Hardware manual Ref 1912...
Страница 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...Ref 1912 DDS HARDWARE 16...
Страница 20: ...Ref 1912 DDS HARDWARE 20...
Страница 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Страница 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Страница 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Страница 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Страница 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Страница 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Страница 405: ......