Power supplies
2.
94
Ref.1912
DDS
HARDWARE
· 44 ·
Power connectors
Terminal strip for mains connection
When connecting the power supplies to mains through terminals L1, L2 and
L3, the phases may be connected in any order.
The ground connection of the cable shield is made from the vertical plate
next to the terminal strip.
The following table shows the values for gap, tightening torque (wire entry
holes) and other data regarding these power screw-on terminals:
F. H2/8
Terminal strip for connection to mains.
T. H2/8
Mains connection terminals. Technical data.
Connector data
PS-25B4
PS-65A
Gap (mm)
10.16
-
Min/max tightening torque (N·m)
1.2/1.5
6/8
Screw thread
M4
M6
Min./max. section (mm²)
0.5/16
16/50
Rated current In (A)
76
150
Wire data
Length to strip (mm)
10
24
L 3
L 2
L 1
Fr om mai ns
N
L1
2
)
The RST phases may be
connected i n any sequence
Cable without connector s
M PC-4x... (mm²)
L2 L3
L1 L2 L3
N ote.
R S T, cl assic nomenclature
L1 L2 L 3, curr ent nomencl atur e
(R) (S) (T)
1
/
/
/
)URPPDLQV
3(
/
7KH567SKDVHVPD\EH
FRQQHFWHGLQDQ\VHTXHQFH
&DEOHZLWKRXWFRQQHFWRUV
03&[PPð
/ /
/ / /
1RWH
567FODVVLFQRPHQFODWXUH
///FXUUHQWQRPHQFODWXUH
5 6 7
MANDATORY.
As for possible high leak currents, use a protection ground
wire with a cross section of at least 10 mm² (Cu) or 16 mm² (Al) or two
protection ground wires with the same cross section as that of the wires
connected to the power supply terminals. Comply with local regulations on
grounding.
MANDATORY.
The equipment must be protected with fuses on the three-
phase supply lines L1, L2 and L3. Follow the instructions given in
Содержание DDS APS-24
Страница 1: ...DRIVE DDS Hardware manual Ref 1912...
Страница 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...Ref 1912 DDS HARDWARE 16...
Страница 20: ...Ref 1912 DDS HARDWARE 20...
Страница 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Страница 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Страница 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Страница 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Страница 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Страница 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Страница 405: ......