2.2 Regenerative power supplies
When referring to regenerative power supplies, we'll use XPS-25 and XPS-
65. They all admit a line voltage between 400 (1-10 %) V AC and 460 (1+10
%) V AC and can return power back to mains. They are:
The
XPS-25
supplies 25 kW and can return 20 kW to mains. It integrates
an auxiliary 24 V DC power supply to feed the control circuits of the
modular drives. Consequently, it will not need an APS-24 to perform this
function.
The
XPS-65
supplies 65 kW and can return 54 kW to mains. It integrates
an auxiliary 24 V DC power supply to feed the control circuits of the
modular drives. Consequently, it will not need an APS-24 to perform this
function.
F. H2/14
Regenerative power supplies.
A.
XPS-25,
B.
XPS-65.
L1
L2
L3
L1
L2
L3
CH1
CH2
CH1
CH2
Ri Re L+
Ri Re L+
A
B
Содержание DDS APS-24
Страница 1: ...DRIVE DDS Hardware manual Ref 1912...
Страница 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...Ref 1912 DDS HARDWARE 16...
Страница 20: ...Ref 1912 DDS HARDWARE 20...
Страница 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Страница 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Страница 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Страница 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Страница 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Страница 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Страница 405: ......