Drives
3.
180
Ref.1912
DDS
HARDWARE
· 142 ·
The following table shows other electrical, mechanical and ambient conditions:
T. H3/18
Compact drives
ACD/SCD
at 400/460 V AC. Technical data.
ACD|CMC
SCD
1.08 1.15 1.25 2.35 2.50
1.15
1.25
2.35
2.50
2.75
Line voltage
3-ph. from 400 (1-10 %) V AC to 460 V AC (1+10 %) V AC
Line frequency
48 ... 62 Hz
Internal power bus voltage
565/650 V DC
565/650 V DC
Filter capacity (µF), 900 V AC
330
560
680
330
560
680
1150
Energy stored in the capacitors
0.5 C·V²
Internal Ballast resistance (
)
Power (W)
75
150
75
150
-
-
-
75
150
-
-
-
-
Energy pulse that can be
dissipated (kWs)
Pulse duration (s)
3.5
0.40
3.5
0.40
-
-
-
3.5
0.40
-
-
-
-
Ballast ON/OFF
768 / 760 V DC
Min. Ballast resistance (
)
75
75
24
18
18
75
75
24
18
18
Speed feedback
Encoder
Encoder
Controlling method
PWM, AC sinewave, vector control
Communication
Serial line to connect to a PC
Interface
Standard analog or digital via SERCOS-II (in all models)
or CAN bus (in all models)
Serial line RS-232/422 (only on CMC models)
Status display
7-segment display
Speed range of analog input
1:8192
Current bandwidth
800 Hz
Speed bandwidth
100 Hz (depends on the motor|drive combination)
Protections
Over-voltage, over-current, over-speed, heat-sink temperature, CPU
temperature, motor temperature, Ballast temperature, hardware
error, overload.
See chapter 14 of the “man_dds_soft.pdf” manual.
Frequency
·1·
0-550 Hz
Power for internal circuits (24 V DC)
Line voltage input
2-ph. from 400 V AC (1-10 %) to 460 V AC (1+10 %)
Line frequency input
48 ... 62 Hz
Line consumption
124.5 mA (400 V AC), 108 mA (460 V AC)
Output voltage, max. current
24 V DC (5 %), 100 mA. Connector X2, pins 1|2.
Ambient conditions
Ambient temperature
·2·
0°C/45°C (32°F/113°F)
Maximum working temperature limit: 60°C/140°F
Storage temperature
-25°C/60°C (-13°F/140°F )
Sealing
IP 2x
Maximum humidity
< 90 % (non condensing at 45°C/113°F)
Maximum installation altitude
2 000 m (6 561 ft) above sea level
Operating vibration
1 g
Shipping vibration
1.5 g
Approx. mass in kg
lb
6.0
13.2
6.0
13.2
5.8
12.7
6.1
13.4
6.1
13.4
6.0
13.2
5.8
12.7
6.1
13.4
6.1
13.4
6.1
13.4
·1·
Higher than 550 Hz only for commercial models
SCD...-L-MDU
(dual-use).
·2·
For high temperatures, refer to derating graphs · power reduction graph ·.
Содержание DDS APS-24
Страница 1: ...DRIVE DDS Hardware manual Ref 1912...
Страница 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...Ref 1912 DDS HARDWARE 16...
Страница 20: ...Ref 1912 DDS HARDWARE 20...
Страница 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Страница 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Страница 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Страница 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Страница 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Страница 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Страница 405: ......