Selection criteria
5.
Ref.1912
· 219 ·
DDS
HARDWARE
2.
The power supply module must be capable of supplying the peak power required by the set of
motors and drives connected to it.
NOTE
. In RPS mode, if the peak power required by the set is greater than 108 kW for XPS power
supplies or greater than 104 kW for RPS power supplies, the set of motors and drives must be divided
into groups and powered by different power supplies.
T. H5/11
Second criteria for selecting the power supply for the whole system.
DANGER.
Never connect the power supplies in parallel!
SECOND CRITERIA
The power supply module must be capable of supplying the peak power required (depending
on the duty cycles) by all the motor-drive sets connected to it.
REQUIRED PEAK POWER:
3
+
2
=
B
kW
Peak power
(depending on the duty cycle)
Power supply
module
In kW
Model
NON-REGENERATIVE
POWER SUPPLIES
If B < 75
PS-25B4
If 75 < B < 195
PS-65A
If B > 195
- Read note -
REGENERATIVE
POWER SUPPLIES
If B < 55
XPS-25
If 55 < B < 108
XPS-65
If B > 108
- Read note -
REGULATED
REGENERATIVE
POWER SUPPLIES
IN RPS MODE
If B < 26
RPS-20
If 26 < B < 59
RPS-45
If 59 < B < 97
RPS-75
If 97 < B < 104
RPS-80
REGULATED
REGENERATIVE
POWER SUPPLIES
IN RB6 MODE
If B < 26
RPS-20
If 26 < B < 55
RPS-45
If 55 < B < 97
RPS-75/RPS-80
NOTE.
When using two power supplies on the same machine, they must make up two independent
groups with their own drives. Only the SERCOS-II ring or CAN bus (if there is one) may be common to
both groups.
Содержание DDS APS-24
Страница 1: ...DRIVE DDS Hardware manual Ref 1912...
Страница 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...Ref 1912 DDS HARDWARE 16...
Страница 20: ...Ref 1912 DDS HARDWARE 20...
Страница 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Страница 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Страница 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Страница 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Страница 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Страница 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Страница 405: ......