Before handling the terminals, proceed as indicated and in the following
order:
With respect to the safety functions, keep in mind that:
WARNING
.
Disconnect the mains voltage at the electrical cabinet.
Wait a few minutes before handling these terminals.
The power supply of the DDS requires time to decrease the voltage of the
power bus to safe values (< 60 V DC or 42.4 Vpeak). The green indicator DC
BUS ON being turned OFF does not mean that the power bus may be handled
or manipulated. The discharge time depends on the number of elements
connected and it is about 4 minutes.
In screw tightening connections, rigorously apply the torque values shown in
this manual for connectors.
Check if the connectors with automatic locking or a locking lever perform their
function satisfactorily.
The machine manufacturer must mark these verifications in the machine
instruction manual.
WARNING.
The
STO
(
S
afe
T
orque
O
ff) safety function do not result in an
electrical disconnection. The DC bus remains under low voltage. Ignoring this
warning may cause electrical shock.
Содержание DDS APS-24
Страница 1: ...DRIVE DDS Hardware manual Ref 1912...
Страница 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...Ref 1912 DDS HARDWARE 16...
Страница 20: ...Ref 1912 DDS HARDWARE 20...
Страница 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Страница 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Страница 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Страница 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Страница 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Страница 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Страница 405: ......