4.5 Connecting the Power Cables
Power is delivered from the MCU to a single FCU and is subsequently distributed to all
other FCUs in the installation via daisychain connections.
Figure 4.5.1 shows the power terminals on the MCU rear panel.
Figure 4.5.1 – MCU Power Terminals
Figure 4.5.2 shows the location of the power terminals (
CON2
and
CON3
) on the FCU
circuit board.
Figure 4.5.2 – FCU CON2 and CON3 (Power Terminals)
TIP: You are advised to ‘tin’ all power wire ends after the wires have been cut to
length. This will make it easier to insert the wire into a terminal connector and will
prevent stray wire strands from causing inadvertent short circuits.