B614
55
732998 - Rev.A_DRAFT
Tr
ansla
tion of the original instruc
tions
ENGLISH
Electronic equipment
Check the integrity of the upper cover and the plastic elec-
tronic board protection.
12
Check that the connectors and wiring are intact.
12
Check that the earth connections are intact.
12
Check that there are no signs of overheating, burning etc. of
electronic components.
12
Check the operation of the circuit breaker and RCD.
12
Control devices
Check that the installed devices and remote controls are in
good condition and that they operate correctly.
12
Deformable edges
Check that they are intact and correctly fastened.
12
Photocells
Check condition, fastening and correct operation.
6
Check the posts, ensuring that they are intact, correctly
fastened and free of deformation etc.
6
Flashing light
Check condition, fastening and correct operation.
12
Access control
Check the proper opening of the barrier only with authorised
user recognition.
12
Hedge
Check: the integrity and fixing of the beam.
6
Foot
Check: the integrity and fixing of the beam.
6
Check the presence and integrity of the reflectors on the foot
and all the other signs and markings necessary.
6
Check the presence and integrity of the lower foot guard.
6
Fork
Check that they are intact and correctly fastened.
6
Check the presence and integrity of all the signs and mark-
ings necessary.
6
Jointed beam
Check that they are intact and correctly fastened.
6
Check the integrity of the wire and the relative signs (max
height allowed, risk of crushing in the beam joint).
6
Complete automation system
Check that the automation system operates correctly, fol-
lowing the set logic, when using the various control devices.
12
Check the proper fluid, smooth movement of the beam
without strange noises.
Check the correct speed during opening and closing and the
respect for the intended slow downs.
12
Check the correct functioning of the manual release: when
the release is activated it must only be possible to move the
beam manually.
Check the presence of the lock cover.
6
Check that the maximum force required to move the beam
by hand is less than 220 N.
6
Check that the encoder is working properly.
6
Check that each pair of photocells is working correctly.
6
Check there is no optical/light interference between the
photocells.
6
If the pedestrian transit cannot be excluded, check the force
limitation curve (EN 12453 and EN 12445 standards). For
non-EU countries, of there are no specific local regulations,
the force must be less than 150 N. ??
6
Check that all necessary signage and warnings are present,
intact and legible: residual risks, exclusive use etc.
12
Check the presence, integrity, legibility of the EC marking
covering the automation system and the DANGER AUTOMATIC
MOVEMENT warning sign
12
14
Periodic replacements
Component
Work cycle periodicity
Spring
200000
Electromechanical actuator
500000
13.2 SPRING REPLACEMENT
Work in progress
13.3 REPLACEMENT OF THE
ELECTROMECHANICAL ACTUATOR
Work in progress