tocells is checked before each closure: the test consists
in breaking the power supply to the TX momentarily
and checking the change of status of the input. If
the test fails the electronic board does not command
the movement.
EXTERNAL LOOPS
!
The magnetic coil detectors must not be used to detect
pedestrians, cycles and motorbikes. If it is not possible
to prevent them passing, other devices such as photocells
are necessary.
(
37
) Connect the magnetic coil detectors to termi-
nal boards J10 (LOOP 1) or J13 (LOOP 2).
LOOP 1
Opening coil
NO contact, connect a detector that commands the
opening of the barrier when a contact is closed
LOOP 2
Transit coil
NO contact, connect a detector that commands the
closure at the disengagement when a contact is closed
The engagement of the loop during the closure inverts
the movement; the barrier cannot close as long as the
loop is engaged
BUS DEVICES
If no BUS 2easy devices are used, leave the BUS 2easy
terminal board free.
See § 10.4 for the connection and orientation.
OUT OUTPUTS
Respect the 100mA max load for each output.
Open Collector Outputs: the activation of the output
and its polarity can be configured by Advanced pro-
gramming.
OUT active
OUT not active
NO polarity
0 V
"
open circuit
NC polarity
open circuit
0 V
"
(
38
) Connect the devices required to terminal
board J20.
24 V
"
FLASHING LIGHT
See § 10.1 for the connection.
MOTOR
(
39
) The motor wire is connected in the factory
for a RH barrier.
Invert the wires if a LH barrier is being installed.
ENCODER
The encoder wire is connected in the factory.
The encoder must always be connected in order for the
automation system to operate.
red
blue