4. INSTALLATION REQUIREMENTS
4.1
MECHANICAL REQUIREMENTS
The mechanical structural components must comply
with the requirements of the EN 12604:2002 and
EN 12605:2001 standards.
Before installing the automation system, the suitability
of the mechanical requirements must be established,
and the necessary work to reach them performed.
The essential mechanical requirements are as follows:
!
Firm ground to support the weight of the barrier with
flat, horizontal paving. There must be no chance of
water accumulating in the installation area.
The presence of enough working space needed for the
installation manoeuvres and subsequent maintenance
operations bearing in mind the opening of the service
door and the positioning/removal of the box and any
other elements.
The thresholds and protrusions of the paving must be
appropriately shaped in order to prevent the risk of
sliding or slipping.
Absence of fixed or mobile obstacles to the movement
of the beam (e.g.: branches, overhead cables, ceilings).
If the installation area presents the possibility of vehicle
impact provided adequate protective structures to
protect the barrier body.
The presence of an unimpeded safety area between the
walls (or other fixed element) and the end of the beam
that is adequate protection against the risk of crushing/
trapping someone.
Suitable safety devices must be installed between the
fixed and moving parts to prevent hands from being
crushed.
For the minimum dimensions to prevent the crushing of
body parts, refer to standard EN 349.
For the safety distances required to prevent danger zones
being reached, refer to ISO 13857.
For the specifics relative to the creation of detection coils,
refer to the relative instructions.