7.2
CONNECTIONS
F
Before making electrical connections, cut off the automa-
tion power supply. If the disconnect switch is not in
view, apply a warning sign stating “WARNING - Mainte-
nance in Progress”.
In Master-Slave configuration, see § 11.
CONTROL DEVICES
(
36
) Connect the devices to the terminal board J6
of the board.
Multiple NO contacts on same input must be connected
in parallel. Multiple NC contacts on same input must be
connected in series.
TERMINAL BOARD J6:
1
OPEN
NO contact, connect a button or other pulse
giver that commands the opening of the
barrier, by closing a contact
2
CLOSE
NO contact, connect a button or other pulse
giver that commands the closure of the bar-
rier, by closing a contact
3
STOP
Configured as STOP (default):
NC contact, connect a button or other pulse
giver that commands the stopping of the
barrier, by opening a contact
If NO device is connected, make a
jump with GND
FSW-CL
Configured as FSW-CL (see
SP
function in
Advanced programming):
NC contact, connect a photoelectric cell or other
device that commands the inversion on open-
ing, by opening a contact during the closure
If NO device is connected, make a
jump with GND
4
EMER
NC contact, connect a button or other pulse
giver that commands the emergency opening
of the barrier, by opening a contact
If NO device is connected, make a
jump with GND
7
GND
Accessories power supply negative and com-
mon contact (1 A max.)
8-9
+
Accessories power supply positive 24 V
"
(1 A max.).
STOP input configured as FSW-CL
For the connection of photocells with relay contact, it
is necessary to configure the STOP input as FSW-CL.
Connect the negative of the transmitter (TX) power
supply of the photocells to an OUT output configured
as Fail-Safe. In this way the functioning of the pho-