12.3 MOTOR AND ENCODER
1. Connect motor M1 to connector J11.
2. Connect the encoder cable of motor M1 to connector J12.
59
!
WARNING: TESTS THE ENCODER CONNECTION BEFORE MOVEMENT
12.4 XB LOCK MOTOR BLOCK AND
MONITORING (OPTIONAL)
!
ALWAYS DISCONNECT the power supply and disconnect the emergency
battery before connecting or disconnecting the motor block in order to
avoid damaging the device.
1. Connect the motor release monitor (IF INSTALLED) to the release
terminal block
60
-C.
2. Connect the motor block to the control board using the wired
connector
60
-
.
3. Program the motor block operation (
EL
EL
) and enable monitoring
(
SU
SU
) (IF INSTALLED).
A
no
no
= XB LOCK motor block disabled.
1
1
= XB LOCK motor block closed in NIGHT-TIME mode
2
2
= XB LOCK motor block closed in NIGHT-TIME and
ONE-DIRECTIONAL mode.
3
3
= XB LOCK motor block closed in NIGHT-TIME mode
and with leaves open
4
4
= XB LOCK motor block closed at the end of each
movement.
Manual release microswitch
C
SU
SU
=
Y
Y
(monitoring enabled - IF INSTALLED)
If the motor block malfunctions, the system signals ERROR 26 on the
display and on SDK EVO.
If there is a power failure, the position of the motor block remains un-
changed. The motor block is always open in manual mode.
1
green
C
Motor block monitoring
(IF INSTALLED)
2
pink
B
Manual release microswitch
3
yellow
4
white
A
Motor block coil
5
brown
1
2
3
2
B
Содержание A1000
Страница 1: ...A1000 EN16005 2012 E1SL fw 3 0 SDK EVO fw 3 0 LK EVO fw 1 2...
Страница 108: ...A1000 108 53221004 Rev A Translation of the original instructions ENGLISH...
Страница 110: ...A1000 110 53221004 Rev A...
Страница 114: ...A1000 114 53221004 Rev A...
Страница 115: ...Translation of the original instructions ENGLISH...