background image

INSTRUCTIONS FOR:

PLASMA CUTTER

MOdel No:

 

PL120/1.V3 

Thank you for purchasing a Sealey plasma cutter. Manufactured to a high standard this product will, if used according to these instructions and properly 

maintained, give you years of trouble free performance.

IMPORTANT

BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS, WARNINGS 

AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL 

INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

  1.  SAFETY INSTRUCTIONS

1.1. 

ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current 

device (RCd) is used. It is particularly important to use an RCd with portable products that are plugged into a supply which is not protected 

by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current device by contacting your Sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  The 

Electricity at Work Act 1989 

requires that all portable electrical appliances, if used on business premises, are tested by a  

 

 

qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.    

 

and use a Portable Appliance Tester.

1.1.4.  ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose.

1.1.6. 

Important:

 ensure that the voltage marked on the appliance matches the power supply to be used and that the supply is protected by  

 

a suitably rated fuse or breaker (see right).

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT 

pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty item  

 

repaired or replaced by a qualified electrician.

1.1.10. 

DO NOT

 use this product with a cable extension reel

.

 

1.1.11.

 

This product requires a 3-PhAse supply, so no plug is fitted. You must  contact a qualified  

 

electrician to ensure that a suitable supply is available. We recommend you discuss the  

 

installation of a industrial round pin plug and socket with your electrician. 

   

WARNING! Reminder, the electrical installation of the plasma cutting unit must only be carried out by a qualified electrician.  

 

Make sure that power supply cable is correctly connected to earth.

  

WARNING! Be very cautious if using a generator to power the plasma cutter. The generator must be self regulating and  

 

 

stable with regard to voltage, waveform and frequency. The output must be greater than the power consumption of the  

 

 

plasma cutter. If any of these requirements is not met the electronics within the plasma cutter may be affected.

 

NOTE:The use of an unregulated generator may be dangerous and will invalidate the warranty on the plasma cutter.

  

WARNING! The plasma cutter may produce voltage surges in the mains supply which can damage other sensitive equipment  

 

(e.g. computers). To avoid this happening it is recommended that the plasma cutter is connected to a power supply that  

 

 

does not feed any sensitive equipment.

1.2. GENERAL SAFETY  

  DANGeR! 

Direct contact with the plasma cutter circuit or torch is dangerous. You MUST unplug the

 

plasma cutter from the mains power    

  supply, (and the compressed air supply) before connecting or disconnecting cables or performing maintenance or service. 

  

Keep the plasma cutter, cables and torch in good condition. 

(Take immediate action to repair or replace damaged parts).

  

Use recommended parts and accessories only. 

(Unapproved parts may be dangerous and will invalidate the warranty).

 

  

Only use the cutting torch provided with the system and ensure that any replacement is of the same type.

  

Use the plasma cutter in a suitable work area. ensure that the area has adequate ventilation as welding/cutting fumes are harmful. For    

  enclosed areas we recommend the use of an extraction system. If you are not able to provide adequate extraction and/or ventilation, wear  

  a respirator suitable for protection against toxic fumes, smoke and gases.

 

 

ensure that there are no obstructions to the flow of clean cool air and that there are no conductive dusts, corrosive vapours or humidity    

  which could enter the unit and cause serious damage.

  

WARNING: 

Use a welding head shield to protect your eyes and avoid exposing skin to the ultraviolet rays given off by the electric arc. 

 

Always wear protective clothing, insulating gloves and shoes. Keep all protective items clean and undamaged.

  

Remove ill-fitting clothing before wearing protective clothing. Remove ties, watches, rings and other loose jewellery and contain long hair.

  

Stand correctly keeping a good footing and balance and ensure that the floor is not slippery. Wear non-slip shoes.

  ensure that  the workpiece is correctly secured before operating the plasma cutter.

 

Avoid unintentional contact with workpiece. Accidental or uncontrolled switching on of the torch may be dangerous and will wear the nozzle. 

  

Keep unauthorised persons away from the work area. Any persons working within the area must wear the same protective items as the    

  cutter operator.

  

DO NOT

 use cables and torch if the insulation is worn or connections are loose.

  

DO NOT

 attempt to fit any unauthorised torches, components or parts to the plasma cutting unit.

  

DO NOT

 cut surfaces that are painted, galvanic coated, oily or greasy.

  

DO NOT

 use cables over 10m in length.

  

DO NOT

 use any metallic structure which is not part of the workpiece to substitute the return cable of the plasma current. 

  

DANGER! DO NOT

 cut near inflammable materials - solids, liquids or gases. Remove all flammable materials such as waste rags etc.

  

DO NOT

 cut containers or pipes which have held flammable materials - gases, liquids or solids. 

DO NOT

 cut materials that have been

  cleaned with chlorinated solvents (or cut near such solvents) as  the arc action may produce toxic gases.

3-PHASE SUPPLY

415V 10A FUSED

(OR 230V 16A FUSED)

MAXIMUM OUTPUT 

WILL BE ACHIEVED ON 

415V SUPPLY 

Original Language Version

Pl120/1.V3    Issue: 2 - 09/03/10

Summary of Contents for PL120/1.V3

Page 1: ...o power the plasma cutter The generator must be self regulating and stable with regard to voltage waveform and frequency The output must be greater than the power consumption of the plasma cutter If any of these requirements is not met the electronics within the plasma cutter may be affected NOTE The use of an unregulated generator may be dangerous and will invalidate the warranty on the plasma cu...

Page 2: ... supply 4 1 An external compressed air supply must be attached to the plasma cutter The supply must produce a working pressure of 65 75psi with a capacity of 120ltr min The maximum entry pressure into the unit must not exceed 90psi 4 2 To avoid excessive wear of the cutter ensure that the air supply is clean and free from moisture We recommend the fitting of a water separator filter unit as shown ...

Page 3: ...ch Clear light 5 6 1 When the Energised Torch clear light fig 3 7 is illuminated the cutting circuit has been activated resulting in either the pilot arc or cutting arc being generated fig 8 fig 6 WARNING Before operating the machine ensure that you read understand and apply Section 1 safety instructions and that you have familiarised yourself with the controls Ensure that the machine is disconnec...

Page 4: ...air humidity oil Excessive pilot arc ignitions in the air Nozzle holder damaged PROBLEM POSSIBLE CAUSE REMEDY 8 TROUBLESHOOTING Slow the cutting speed Adjust the torch tilt Confirm workpiece thickness and re check technical data Replace electrode and nozzle Increase cutting speed Decrease the distance between torch and workpiece Replace electrode and nozzle Check warning lights and take appropriat...

Page 5: ...nd maintained according to the instructions 10 7 Cables The welding cutting cables should be kept as short as possible and should be positioned close together running at or close to the floor level 10 8 Equipotential bonding Bonding of all metallic components in the welding cutting installation and adjacent to it should be considered However metallic components bonded to the workpiece will increas...

Reviews: