11.3 ADJUSTING THE MECHANICAL STOPS
!
The adjustment of the mechanical stops is indispensable for correct
operation of the automation.
The carriages must come into contact with the mechanical stops posi-
tioned at stroke end in opening and closing.
STOPS ON OPENING
1. Loosen the screw
40
-
to release the mechanical stop.
2. Open the leaf completely
41
-
.
3. Bring the pad of the mechanical stop and the carriage into contact
41
-
.
4. Tighten the screw to lock the mechanical stop
40
-
.
SINGLE LEAF CLOSING STOPS
With closed door the carriage must be in full contact with the me-
chanical stop.
1. Loosen the screw to release the mechanical stop
40
-
.
2. Close the leaf.
3. Bring the pad of the mechanical stop and the carriage into contact
41
-
.
4. Tighten the screw to lock the mechanical stop
41
-
.
DOUBLE LEAF CLOSING STOPS
!
In double leaf automations, the leaves must close at the head section
centre line.
1. Move the leaves in the closed door position.
2. For each leaf, ensure the carriage is in full contact with the closing
stop pad.
Should adjustment be required:
3. Bring the pad of the mechanical stop and the carriage into contact
42
-
.
4. Tighten the screw to lock the mechanical stop
40
-
.
Содержание A1000
Страница 1: ...A1000 EN16005 2012 E1SL fw 3 0 SDK EVO fw 3 0 LK EVO fw 1 2...
Страница 108: ...A1000 108 53221004 Rev A Translation of the original instructions ENGLISH...
Страница 110: ...A1000 110 53221004 Rev A...
Страница 114: ...A1000 114 53221004 Rev A...
Страница 115: ...Translation of the original instructions ENGLISH...