A1000
64
532210 04 - Rev.A
Tr
ansla
tion of the original instruc
tions
ENGLISH
CLOSING EMERGENCY input WITHOUT MEMORY (34) AND WITH MEMORY (35)
CLOSING EMERGENCY input WITHOUT MEMORY (34) AND WITH MEMORY (35)
input.
input.
--
With the input active,
With the input active, the leaves close.
-
The Emergency priority order is as follows: Open , Stop , Close.
-
The input configured as CLOSING EMERGENCY
CLOSING EMERGENCY behaves differ-
ently depending on whether it is programmed with or without
memory:
1. without memory , once the input is deactivated the leaves no
longer remain Closed and return to their previous status.
2. with memory, once the input is deactivated the leaves remain
Closed until the RESET command is given.
-
these functions are active in NIGHT-TIME mode.
-
these functions are not active in MANUAL mode.
-
activation of this input lights up the EMERG green LED on the
board.
PARTIAL
PARTIAL
TWO-DIRECTIONAL AUTOMATIC
operating mode input (45)
operating mode input (45)
--
With the input active,
With the input active, it forces a PARTIAL operating mode.
--
When this input is deactivated, it forces a
When this input is deactivated, it forces a TOTAL operating mode
to be set.
NIGHT-TIME MODE input (43)
--
With the active input
With the active input configured in this way, it forces the NIGHT-
TIME operating mode to be set.
--
When this input is deactivated,
When this input is deactivated, one exits from NIGHT-TIME mode.
MANUAL MODE input (44)
--
With the active input
With the active input configured in this way, it forces the manual
operating mode to be set.
--
When this input is deactivated
When this input is deactivated, one exits from MANUAL mode.
Interlock operating mode input (46)
-
The input becomes active only if the Interlock function is pro-
grammed from the Intercom menu via SDK EVO .
TIMER input (60)
--
With this input active
With this input active the TIMER function is on.
--
When this input is deactivated,
When this input is deactivated, the TIMER function is turned off.
V
G
I1
I2
G
I3
I4
V
J21
V
+24V
accessories power supply
I4
Input4
configurable (programming)
I3
Input3
configurable (programming)
G
GND
Accessories power supply negative and Common
contacts
I2
Input2
configurable (programming)
I1
Input1
configurable (programming)
G
GND
Accessories power supply negative and Common
contacts
V
+24V
accessories power supply
70
Содержание A1000
Страница 1: ...A1000 EN16005 2012 E1SL fw 3 0 SDK EVO fw 3 0 LK EVO fw 1 2...
Страница 108: ...A1000 108 53221004 Rev A Translation of the original instructions ENGLISH...
Страница 110: ...A1000 110 53221004 Rev A...
Страница 114: ...A1000 114 53221004 Rev A...
Страница 115: ...Translation of the original instructions ENGLISH...